Glucose recovery with bare and hydrogel-coated microdialysis probes: Experiment and simulation of temporal effects

被引:7
作者
Norton, Lori W. [1 ]
Yuan, Fan [1 ]
Reichert, W. Monty [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
D O I
10.1021/ac061234p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In vitro microdialysis glucose sampling was used to test the transient and steady-state suitability of antifouling hydrogel coatings, composed of 2-hydroxyethyl methacrylate, vinylpyrrolidinone, and poly(ethylene glycol). The in vitro glucose diffusion coefficients of bare microdialysis membranes and hydrogel coatings were determined experimentally to be 1.1 x 10(-6) and 3.2 x 10(-6) cm(2)/s, respectively. These values were used to numerically simulate the effect of the hydrogel on glucose transport across the microdialysis membrane using a convection-diffusion transport model. The times for dialysate at the exit of the bare and hydrogel-coated microdialysis probes to reach 95% of steady state were calculated to be 20 and 66 s, respectively. However, the experimental data showed that 95% of steady-state glucose recoveries were reached after 4-5 min. Numerical simulations incorporating the Taylor dispersion in the outlet tubing showed the time difference was caused almost completely by convective transport in the outlet tubing with negligible contribution from analyte profile broadening. These data indicated that the hydrogel coatings imposed 44% reduction in glucose permeability and consequently 26% reduction in the percent recovery. The effect of hydrogel coatings on the time to reach the steady-state recovery was insignificant compared with the time required for convection of glucose in the outlet tubing.
引用
收藏
页码:445 / 452
页数:8
相关论文
共 37 条
[1]   Hydrogel networks of poly(ethylene oxide) star-molecules supported by expanded polytetrafluoroethylene membranes: Characterization, biocompatibility evaluation and glucose diffusion characteristics [J].
Alexandre, E ;
Schmitt, B ;
Boudjema, K ;
Merrill, EW ;
Lutz, PJ .
MACROMOLECULAR BIOSCIENCE, 2004, 4 (07) :639-648
[2]   ON THE DISPERSION OF A SOLUTE IN A FLUID FLOWING THROUGH A TUBE [J].
ARIS, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1956, 235 (1200) :67-77
[3]  
Bird R.B., 2006, TRANSPORT PHENOMENA, Vsecond, DOI 10.1002/aic.690070245
[4]   LONG-TERM CONTINUOUS GLUCOSE MONITORING WITH MICRODIALYSIS IN AMBULATORY INSULIN-DEPENDENT DIABETIC-PATIENTS [J].
BOLINDER, J ;
UNGERSTEDT, U ;
ARNER, P .
LANCET, 1993, 342 (8879) :1080-1085
[5]   STEADY-STATE THEORY FOR QUANTITATIVE MICRODIALYSIS OF SOLUTES AND WATER INVIVO AND INVITRO [J].
BUNGAY, PM ;
MORRISON, PF ;
DEDRICK, RL .
LIFE SCIENCES, 1990, 46 (02) :105-119
[6]  
Chemical Rubber Company (CRC), 1984, CRC HDB CHEM PHYS
[7]   MICRODIALYSIS SAMPLING COUPLED ONLINE TO FAST MICROBORE LIQUID-CHROMATOGRAPHY [J].
CHEN, AQ ;
LUNTE, CE .
JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) :29-35
[8]  
Cussler E L., 2009, Diffusion: Mass Transfer in Fluid Systems, V3rd edn
[9]  
Fogler H. S., 1999, ELEMENTS CHEM REACTI
[10]   ROLE OF CELL-SHAPE IN GROWTH-CONTROL [J].
FOLKMAN, J ;
MOSCONA, A .
NATURE, 1978, 273 (5661) :345-349