The Everolimus-Eluting Stent in Real-World Patients 6-Month Follow-Up of the X-SEARCH (Xience V Stent Evaluated at Rotterdam Cardiac Hospital) Registry

被引:50
作者
Onuma, Yoshinobu [1 ]
Kukreja, Neville [1 ]
Piazza, Nicolo [1 ]
Eindhoven, Jannet [1 ]
Girasis, Chrysafios [1 ]
Schenkeveld, Lisanne [1 ]
van Domburg, Ron [1 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
关键词
everolimus-eluting stent; all-comer registry; sirolimus-eluting stent; paclitaxel-eluting stent; CORONARY-ARTERY-DISEASE; BARE-METAL; SIROLIMUS; IMPLANTATION; THROMBOSIS; COVERAGE;
D O I
10.1016/j.jacc.2009.05.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to investigate the impact of everolimus-eluting stents (EES) in comparison with bare-metal stents (BMS), sirolimus-eluting stents (SES), and paclitaxel-eluting stents (PES) on the 6-month clinical outcomes in an all-comer population. Background EES have been shown to be effective in the context of randomized trials with selected patients. The effect of EES implantation in more complex, unselected patients cannot be directly extrapolated from these findings. Methods In total, 649 consecutive unselected patients treated exclusively with EES were enrolled. Six-month clinical end points were compared with 3 historical cohorts (BMS, n = 450; SES, n = 508; and PES, n = 576). Major adverse cardiac events (MACE) were defined as a composite of all-cause mortality, myocardial infarction, or target vessel revascularization (TVR). Results The patients treated with EES were older, presented more frequently with acute myocardial infarction, and had more complicated lesions than the other groups. The EES group demonstrated a higher incidence of all-cause mortality than the SES group and a lower incidence of TVR than the BMS group. Multivariate adjustment demonstrated that BMS was associated with higher TVR and MACE risk than EES (adjusted hazard ratio [HR] for TVR: 2.02 [95% confidence interval (CI): 1.11 to 3.67]; adjusted HR for MACE: 2.15 [95% CI: 1.36 to 3.42]); that SES had a clinical outcome similar to that of EES, and that PES had a higher risk of MACE than did EES (adjusted HR: 1.57 [95% CI: 1.02 to 2.44]). Conclusions This study suggests that the use of EES in an unselected population may be as safe as and more effective than BMS, may be as safe and effective as SES, may be as safe as PES, and may be more effective than PES. (J Am Coll Cardiol 2009; 54: 269-76) (C) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:269 / 276
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 2008, Modern epidemiology
[2]  
Cook Stephane, 2008, EuroIntervention, V3, P535, DOI 10.4244/EIJV3I5A95
[3]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[4]  
Daemen J, 2008, NEW ENGL J MED, V358, P2641, DOI 10.1056/NEJMc080368
[5]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[6]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[7]   Endothelial cell recovery between comparator polymer-based drug-eluting stents [J].
Joner, Michael ;
Nakazawa, Gaku ;
Finn, Aloke V. ;
Quee, Shawn Chin ;
Coleman, Leslie ;
Acampado, Eduardo ;
Wilson, Patricia S. ;
Skorija, Kristi ;
Cheng, Qi ;
Xu, Xin ;
Gold, Herman K. ;
Kolodgie, Frank D. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (05) :333-342
[8]  
Khattab Ahmed A, 2008, EuroIntervention, V3, P566, DOI 10.4244/EIJV3I5A102
[9]   Incomplete neointimal coverage of sirolimus-eluting stents - Angioscopic findings [J].
Kotani, Jun-ichi ;
Awata, Masaki ;
Nanto, Shinsuke ;
Uematsu, Masaaki ;
Oshima, Fusako ;
Minamiguchi, Hitoshi ;
Mintz, Gary S. ;
Nagata, Seiki .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (10) :2108-2111
[10]   Primary Percutaneous Coronary Intervention for Acute Myocardial Infarction Long-Term Outcome After Bare Metal and Drug-Eluting Stent Implantation [J].
Kukreja, Neville ;
Onuma, Yoshinobu ;
Garcia-Garcia, Hector ;
Daemen, Joost ;
van Domburg, Ron ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (02) :103-110