Voltammetric heparin-selective electrode based on thin liquid membrane with conducting polymer-modified solid support

被引:126
作者
Guo, Jidong [1 ]
Amemiya, Shigeru [1 ]
机构
[1] Univ Pittsburgh, Dept Chem, Pittsburgh, PA 15260 USA
关键词
D O I
10.1021/ac061003i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, solid-supported voltammetric ion-selective electrode to detect anticoagulant/antithrombotic heparin at polarizable poly(vinyl chloride) (PVC) membrane/water interfaces was developed. An similar to 3-4.5-mu m-thick PVC membrane plasticized with 2-nitrophenyl octyl ether was supported on a gold electrode modified with a poly(3-octylthiophene) (POT) film as an ion-to-electron transducer. Charge transport through the PVC-covered POT film is electrochemically reversible, as demonstrated by cyclic voltammetry with nonpolarizable membrane/water interfaces. In addition to the fast charge transport, adequate redox capacity of the POT film and a small ohmic potential drop in the thin PVC membrane enable ion transfer voltammetry at polarizable macroscopic membrane/water interfaces in a standard three-electrode cell. Reversible ClO4- transfer at the interfaces coupled with oxidation of a neutral POT film was examined by cyclic voltammetry to determine the distribution of the applied potential to the two polarizable interfaces by convolution technique. Interfacial adsorption and desorption of heparin facilitated by octadecyltrimethylammonium were studied also by cyclic voltammetry and convolution technique to demonstrate that the processes are electrochemically irreversible. Stripping voltammetry based on the interfacial processes gives a low detection limit of 0.005 unit/mL heparin in a saline solution, which is slightly lower than the detection limit of most sensitive heparin sensors reported so far (0.01 unit/mL).
引用
收藏
页码:6893 / 6902
页数:10
相关论文
共 67 条
[21]   RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[22]  
GIRAULT HHJ, 1989, ELECTROANAL CHEM, V15, P1
[23]   Voltammetric detection of heparin at polarized blood plasma/1,2-dichloroethane interfaces [J].
Guo, JD ;
Yuan, Y ;
Amemiya, S .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5711-5719
[24]  
Henn D, 2000, ELECTROANAL, V12, P1263, DOI 10.1002/1521-4109(200011)12:16<1263::AID-ELAN1263>3.0.CO
[25]  
2-B
[26]   Antithrombotic therapy for venous thromboembolic disease [J].
Hyers, TM ;
Agnelli, G ;
Hull, RD ;
Morris, TA ;
Samama, M ;
Tapson, V ;
Weg, JG .
CHEST, 2001, 119 (01) :176S-193S
[27]  
IMBEAUX JC, 1973, J ELECTROANAL CHEM, V44, P169, DOI 10.1016/S0022-0728(73)80244-X
[28]   The theory of liquid ion-exchange membrane ion-selective electrodes based on the concept of the mixed ion-transfer potential [J].
Kakiuchi, Takashi ;
Senda, Mitsugi .
Bulletin of the Chemical Society of Japan, 1984, 57 (07) :1801-1808
[29]   THEORY AND APPLICATIONS OF ION-SELECTIVE ELECTRODES .4A. [J].
KORYTA, J .
ANALYTICA CHIMICA ACTA, 1982, 139 (JUL) :1-51
[30]   Amperometry of heparin polyion using a rotating disk electrode coated with a plasticized PVC membrane [J].
Langmaier, J ;
Olsák, J ;
Samcová, E ;
Samec, Z ;
Trojánek, A .
ELECTROANALYSIS, 2006, 18 (02) :115-120