Evaluation by fluorescence resonance energy transfer of the stability of nonviral gene delivery vectors under physiological conditions

被引:84
作者
Itaka, K
Harada, A
Nakamura, K
Kawaguchi, H
Kataoka, K [1 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Mat Sci, Bunkyo Ku, Tokyo 1138656, Japan
[2] Univ Tokyo, Fac Med, Dept Orthopaed Surg, Bunkyo Ku, Tokyo 1138655, Japan
关键词
D O I
10.1021/bm025527d
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The stability in physiological medium of polyplex- and lipoplex-type nonviral gene vectors was evaluated by detecting the conformational change of complexed plasmid DNA (pDNA) labeled simultaneously with fluorescein (energy donor) and X-rhodamine (energy acceptor) through fluorescence resonance energy transfer (FRET). Upon mixing with cationic components, such as LipofectAMINE, poly(L-lysine), and poly(ethylene glycol)-poly(L-lysine) block copolymer (PEG-PLys), the fluorescence spectrum of doubly labeled pDNA underwent a drastic change due to the occurrence of FRET between the donor-acceptor pair on pDNA taking a globular conformation (condensed state) through complexation. The measurement was carried out also in the presence of 20% serum, under which conditions FRET from condensed pDNA was clearly monitored without interference from coexisting components in the medium, allowing evaluation of the condensed state of pDNA in nonviral gene vectors under physiological conditions. Serum addition immediately induced a sharp decrease in FRET for the LipofectAMINE/pDNA (lipoplex) system, which was consistent with the sharp decrease in the transfection efficiency of the lipoplex system in serum-containing medium. In contrast, the PEG-PLys/pDNA polyplex (polyion complex micelle) system maintained appreciable transfection efficiency even in serum-containing medium, and FRET efficiency remained constant for up to 12 h, indicating the high stability of the polyion complex micelle under physiological conditions.
引用
收藏
页码:841 / 845
页数:5
相关论文
共 22 条
[11]  
ITAKA K, 2001, P INT S CONTR REL BI, V28, P1157
[12]   Spontaneous formation of polyion complex micelles with narrow distribution from antisense oligonucleotide and cationic block copolymer in physiological saline [J].
Kataoka, K ;
Togawa, H ;
Harada, A ;
Yasugi, K ;
Matsumoto, T ;
Katayose, S .
MACROMOLECULES, 1996, 29 (26) :8556-8557
[13]   Block copolymer micelles for drug delivery: design, characterization and biological significance [J].
Kataoka, K ;
Harada, A ;
Nagasaki, Y .
ADVANCED DRUG DELIVERY REVIEWS, 2001, 47 (01) :113-131
[14]   Remarkable increase in nuclease resistance of plasmid DNA through supramolecular assembly with poly(ethylene glycol) poly(L-lysine) block copolymer [J].
Katayose, S ;
Kataoka, K .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (02) :160-163
[15]   Water-soluble polyion complex associates of DNA and poly(ethylene glycol)-poly(L-lysine) block copolymer [J].
Katayose, S ;
Kataoka, K .
BIOCONJUGATE CHEMISTRY, 1997, 8 (05) :702-707
[16]   Dynamic changes in the characteristics of cationic lipidic vectors after exposure to mouse serum: implications for intravenous lipofection [J].
Li, S ;
Tseng, WC ;
Stolz, DB ;
Wu, SP ;
Watkins, SC ;
Huang, L .
GENE THERAPY, 1999, 6 (04) :585-594
[17]   Biodegradable polyester, poly[α-(4 aminobutyl)-L-glycolic acid], as a non-toxic gene carrier [J].
Lim, YB ;
Han, SO ;
Kong, HU ;
Lee, Y ;
Park, JS ;
Jeong, B ;
Kim, SW .
PHARMACEUTICAL RESEARCH, 2000, 17 (07) :811-816
[18]  
*PANV CORP, 1999, FAQ LAB IT NUCL AC L
[19]   Interactions of polymeric and liposomal gene delivery systems with extracellular glycosaminoglycans:: physicochemical and transfection studies [J].
Ruponen, M ;
Ylä-Herttuala, S ;
Urtti, A .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1999, 1415 (02) :331-341
[20]   Gene transfer mediated by cationic lipids: Lack of a correlation between lipid mixing and transfection [J].
Stegmann, T ;
Legendre, JY .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1997, 1325 (01) :71-79