Anatomic suitability of the C1-C2 complex for pedicle screw fixation

被引:264
作者
Resnick, DK [1 ]
Lapsiwala, S [1 ]
Trost, GR [1 ]
机构
[1] Univ Wisconsin, Sch Med, Dept Neurol Surg, Clin Sci Ctr K4 834, Madison, WI 53792 USA
关键词
atlantoaxial instability; pedicle screw; spinal trauma; transarticular screw;
D O I
10.1097/00007632-200207150-00003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design and Objectives. A computed tomography (CT) study of 60 consecutive patients (120 sides) was performed to assess suitability for either transarticular or pedicle screw fixation. Summary of Background Data. A C1 lateral mass and C2 pedicle screw fixation with a rigid cantilever beam system has been described. The anatomic constraints relevant for this technique have not. Methods. Fifty consecutive patients underwent standard CT of the cervical spine. Pedicle and transarticular screw trajectories were plotted, and the maximum safe diameter for screw placement was determined for each trajectory. Also, trajectories were plotted in 10 additional patients with known craniocervical junction abnormalities using three-dimensional (3-D) imaging and computer-aided navigation tools. Screw placement was considered feasible if a 4-mm diameter trajectory could be plotted without impingement on neural or vascular structures. Results. Four-millimeter diameter pedicle screws could be placed in 91 of 100 C2 pedicles in the CT studies and in 20 of 20 pedicles in the 3-D studies. Four-millimeter diameter C1-C2 transarticular screws could be placed in 94 of 100 sides in the CT study and in 19 of 20 sides in the 3-D study, Four sides could tolerate a C2 pedicle screw and not a transarticular screw; the opposite situation existed in five sides. Placement of screws into C1 was not an issue in any patient. The mean maximum diameter of potential transarticular screws was 6,5 mm, and the mean maximum diameter of the pedicle screws was 5.3 mm (P<0.01). Conclusions. C1-C2 pedicle screw fixation is a technique that appears to be widely applicable and may represent an alternative fixation technique in selected patients.
引用
收藏
页码:1494 / 1498
页数:5
相关论文
共 24 条
[11]   C1-c2 transarticular screw fixation: Technical aspects [J].
Haid, RW .
NEUROSURGERY, 2001, 49 (01) :71-74
[12]   Posterior C1-C2 fusion with polyaxial screw and rod fixation [J].
Harms, J ;
Melcher, RP .
SPINE, 2001, 26 (22) :2467-2471
[13]  
Kazan S, 2000, CLIN ANAT, V13, P237, DOI 10.1002/1098-2353(2000)13:4<237::AID-CA2>3.0.CO
[14]  
2-K
[15]   Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique [J].
Madawi, AA ;
Casey, ATH ;
Solanki, GA ;
Tuite, G ;
Veres, R ;
Crockard, HA .
JOURNAL OF NEUROSURGERY, 1997, 86 (06) :961-968
[16]  
Magerl F, 1987, STABLE POSTERIOR FUS, P322
[17]   Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws [J].
Mandel, IM ;
Kambach, BJ ;
Petersilge, CA ;
Johnstone, B ;
Yoo, JU .
SPINE, 2000, 25 (12) :1542-1547
[18]   POSTERIOR ATLANTOAXIAL FACET SCREW FIXATION [J].
MARCOTTE, P ;
DICKMAN, CA ;
SONNTAG, VKH ;
KARAHALIOS, DG ;
DRABIER, J .
JOURNAL OF NEUROSURGERY, 1993, 79 (02) :234-237
[19]   Biomechanical comparison of C1-C2 posterior fixations - Cable, graft, and screw combinations [J].
Naderi, S ;
Crawford, NR ;
Song, GS ;
Sonntag, VKH ;
Dickman, CA .
SPINE, 1998, 23 (18) :1946-1955
[20]   The anatomical suitability of the C1-2 complex for transarticular screw fixation [J].
Paramore, CG ;
Dickman, CA ;
Sonntag, VKH .
JOURNAL OF NEUROSURGERY, 1996, 85 (02) :221-224