Quantitative analysis of triglycerides using atmospheric pressure chemical ionization mass spectrometry

被引:114
作者
Byrdwell, WC
Emken, EA
Neff, WE
Adlof, RO
机构
[1] FQS, NCAUR, USDA, Peoria
[2] FQS, NCAUR, USDA, Peoria, IL 61604
关键词
D O I
10.1007/BF02522685
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Atmospheric pressure chemical ionization-mass spectrometry (APCI-MS) was used for quantitative analysis of triglycerides (TG) separated by reverse-phase high-performance liquid chromatography. APCI-MS was used for analysis of mono-acid TG standards containing deuterated internal standard, of a synthetic mixture of heterogeneous TG, of randomized and normal soybean oils and of randomized and normal lard samples. Quantitation of the TG by four approaches based on APCI-MS were compared, and these were compared to quantitation obtained using liquid chromatography (LC) with flame-ionization detection (FID). The APCI-MS methods were based on (i) calibration curves from data for mono-acid TG standards, (ii) response factors obtained from a synthetic mixture of TG, (iii) response factors calculated from comparison of randomized samples to their statistically expected compositions, and (iv) response factors calculated from comparison of fatty acid (FA) compositions calculated from TG compositions to FA compositions obtained by calibrated gas chromatography (GC) with FID. Response factors derived from a synthetic mixture were not widely applicable to samples of disparate composition. The TG compositions obtained using APCI-MS data without application of response factors had average relative errors very similar to those obtained using LC-FID. Numerous TG species were identified using LC/APCI-MS which were undetected using LC-FID. Two quantitation methods, based on response factors calculated from randomized samples or on response factors calculated from FA compositions, both gave similar results for all samples. The TG compositions obtained using response factors calculated from FA compositions showed less average relative error than was obtained from LC-FID data, and were in good agreement with predicted compositions for the synthetic mixture and for randomized soybean oil and lard samples.
引用
收藏
页码:919 / 935
页数:17
相关论文
共 20 条
[1]
SYNTHESIS OF CIS AND TRANS METHYL 8-OCTADECENOATE-D2 AND 13-OCTADECENOATE-D2 AND D4 ISOMERS [J].
ADLOF, RO ;
MILLER, WR ;
EMKEN, EA .
JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 1978, 15 :625-636
[2]
BAILEY AE, 1964, BAILEYS IND OIL FAT, P965
[3]
ANALYSIS OF TRIGLYCERIDES USING ATMOSPHERIC-PRESSURE CHEMICAL LONIZATION MASS-SPECTROMETRY [J].
BYRDWELL, WC ;
EMKEN, EA .
LIPIDS, 1995, 30 (02) :173-175
[4]
DAUBERT BF, 1949, J AM OIL CHEM SOC, V26, P556
[5]
GLASS RL, 1969, J DAIRY SCI, V52, P1289
[6]
QUANTITATIVE ANALYSIS OF TRIGLYCERIDE MIXTURES BY MASS SPECTROMETRY [J].
HITES, RA .
ANALYTICAL CHEMISTRY, 1970, 42 (14) :1736-&
[7]
STRATEGY OF GLYCEROLIPID SEPARATION AND QUANTITATION BY COMPLEMENTARY ANALYTICAL TECHNIQUES - PLENARY LECTURE [J].
KUKSIS, A ;
MARAI, L ;
MYHER, JJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 273 (01) :43-66
[8]
ZERO TRANS MARGARINES - PREPARATION, STRUCTURE, AND PROPERTIES OF INTER-ESTERIFIED SOYBEAN OIL SOY TRISATURATE BLENDS [J].
LIST, GR ;
EMKEN, EA ;
KWOLEK, WF ;
SIMPSON, TD ;
DUTTON, HJ .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1977, 54 (10) :408-413
[9]
ANALYSIS OF HUMAN BLOOD-PLASMA TRIACYLGLYCEROLS USING CAPILLARY GAS-CHROMATOGRAPHY, SILVER ION THIN-LAYER CHROMATOGRAPHIC FRACTIONATION AND DESORPTION CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
MARES, P ;
REZANKA, T ;
NOVAK, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 568 (01) :1-10
[10]
MYHER JJ, 1995, J CHROMATOGR B, V671, P3, DOI 10.1016/0378-4347(95)00178-L