Study of the influence of the aspect ratio on efficiency, flow resistance and retention factors of packed capillary columns in pressure- and electrically-driven liquid chromatography

被引:23
作者
Eeltink, S
Rozing, GP
Schoenmakers, PJ
Kok, WT
机构
[1] Univ Amsterdam, Dept Chem Engn, Polymer Anal Grp, NL-1018 WV Amsterdam, Netherlands
[2] Agilent Technol, Pharmaceut Solut, Life Sci & Chem Anal, D-76337 Waldbronn, Germany
关键词
electrochromatography; aspect ratio; efficiency; wall effects; flow resistance; retention factor;
D O I
10.1016/j.chroma.2004.06.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The influence of the aspect ratio, rho (rho = column diameter/particle diameter), on column parameters such as efficiency, retention factors and flow resistance was studied in both high-performance liquid chromatography and capillary electrochromatography with packed capillary columns. In order to compare the true efficiencies of different columns, a procedure to account for external band broadening was applied. High efficiencies (reduced plate height h approximate to 2) were obtained with capillary columns with internal diameters of 150-, 100-, and 75-mum, packed with 10-mum particles. In contrast to previous reports in the literature, no significant improvements in efficiency or flow resistance were observed when the aspect ratio of such columns was decreased. Our observations suggest that the wall effect in these types of columns is not significant. When the aspect ratio was decreased by increasing the particle size, a decrease in reduced plate height was observed. However, the results of flow resistance measurements showed that the latter effect should be attributed to differences in packing and particle batch quality rather than to differences in the aspect ratio. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 28 条
[1]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[2]   Organo-silica nano-particles used in ultrahigh-pressure liquid chromatography [J].
Cintrón, JM ;
Colón, LA .
ANALYST, 2002, 127 (06) :701-704
[3]   EFFECT OF COLUMN DIAMETER ON PLATE HEIGHT IN HIGH-SPEED LIQUID-CHROMATOGRAPHY USING PELLICULAR AND PERFUSED PARTICLES IN PACKED CAPILLARIES [J].
COLE, LJ ;
SCHULTZ, NM ;
KENNEDY, RT .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (05) :433-439
[4]   Packing columns for capillary electrochromatography [J].
Colón, LA ;
Maloney, TD ;
Fermier, AM .
JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) :43-53
[5]  
DOLAN JW, 1989, TROUBLESHOOTING
[6]   Recent applications in capillary electrochromatography [J].
Eeltink, S ;
Rozing, GR ;
Kok, WT .
ELECTROPHORESIS, 2003, 24 (22-23) :3935-3961
[7]  
Giddings J.C., 1991, Unified separation science
[8]   Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry [J].
Hopfgartner, G ;
Bourgogne, E .
MASS SPECTROMETRY REVIEWS, 2003, 22 (03) :195-214
[9]   Preparation and evaluation of slurry-packed liquid chromatography microcolumns with inner diameters from 12 to 33 mu m [J].
Hsieh, SC ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1212-1217
[10]   SEPARATION EFFICIENCY OF SLURRY-PACKED LIQUID-CHROMATOGRAPHY MICROCOLUMNS WITH VERY SMALL INNER DIAMETERS [J].
KARLSSON, KE ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1662-1665