Carotid artery stents: Early and intermediate follow-up with Doppler US

被引:71
作者
Robbin, ML
Lockhart, ME
Weber, TM
Vitek, JJ
Smith, JK
Yadav, J
Mathur, A
Iyer, SS
Roubin, GS
机构
[1] UNIV ALABAMA,DIV CARDIOVASC DIS,BIRMINGHAM,AL 35233
[2] ATLANTA CARDIOL GRP,ATLANTA,GA
关键词
carotid arteries; flow dynamics; stenosis or obstruction;
D O I
10.1148/radiology.205.3.9393531
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To determine whether ultrasound (US) is a sensitive follow-up method after placement of a carotid artery stent for the detection of significant stenosis, occlusion, and other complications at early and intermediate follow-up. MATERIALS AND METHODS: Doppler US examinations were performed after stent placement in 170 carotid arteries in 119 patients with angiographic correlation. Prospective diagnostic US criteria for stenosis were peak-systolic velocity greater than 1.25 m/sec, internal carotid artery (TCA) to common carotid artery (CCA) peak-systolic velocity ratio of greater than or equal to 3:1, and intrastent doubling of peak-systolic velocity. Retrospective criteria for stenosis were also applied: peak-systolic velocity greater than 1.7 m/sec, ICA end-diastolic velocity greater than 0.4 m/sec, ICA/CCA peak-systolic velocity ratio greater than 2.0, and ICA/CCA end-diastolic velocity ratio greater than 2.4. RESULTS: Eighty-seven immediate and 83 intermediate (average, 7.3 months) follow-up US examinations were performed. Two stent occlusions were detected. One or more prospective US criteria were abnormal in 26 arteries with a stent. One or more retrospective criteria were positive in 47 arteries. Angiography showed corresponding findings, with only one significant stenosis (63%) in the ICA stents. Moderate collapse of a CCA stent was depicted at US. CONCLUSION: Only one significant recurrent stenosis was detected, and no significant stenoses were missed at US. US successfully depicted carotid artery stent occlusion and a moderate stent collapse. Sensitivity in the detection of intrastent stenosis is promising. Further study to refine US criteria in a study with longer term follow-up is needed owing to the lack of significant recurrent stenosis in the intermediate follow-up group.
引用
收藏
页码:749 / 756
页数:8
相关论文
共 19 条
[1]
Bluth E I, 1988, Radiographics, V8, P487
[2]
BRANAS CC, 1994, J ULTRAS MED, V13, P121
[3]
Determination of sixty percent or greater carotid artery stenosis by duplex Doppler ultrasonography [J].
Carpenter, JP ;
Lexa, FJ ;
Davis, JT .
JOURNAL OF VASCULAR SURGERY, 1995, 22 (06) :697-705
[4]
CAROTID SONOGRAPHY [J].
CARROLL, BA .
RADIOLOGY, 1991, 178 (02) :303-313
[5]
CARROLL BA, 1989, J ULTRAS MED, V8, P535
[6]
FONTENELLE LJ, 1994, AM SURGEON, V60, P864
[7]
CAROTID-ARTERY - PROSPECTIVE BLINDED COMPARISON OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY AND DUPLEX US [J].
HUSTON, J ;
LEWIS, BD ;
WIEBERS, DO ;
MEYER, FB ;
RIEDERER, SJ ;
WEAVER, AL .
RADIOLOGY, 1993, 186 (02) :339-344
[8]
KREMKAU FW, 1993, DIAGNOSTIC ULTRASOUN, P192
[9]
SCREENING FOR ASYMPTOMATIC INTERNAL CAROTID-ARTERY STENOSIS - DUPLEX CRITERIA FOR DISCRIMINATING 60-PERCENT TO 99-PERCENT STENOSIS [J].
MONETA, GL ;
EDWARDS, JM ;
PAPANICOLAOU, G ;
HATSUKAMI, T ;
TAYLOR, LM ;
STRANDNESS, DE ;
PORTER, JM .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (06) :989-994
[10]
*N AM SYMPT CAR EN, 1991, NEW ENGL J MED, V325, P445