Analysis of peptides using partial (no discharge) atmospheric pressure chemical ionization conditions with ion trap mass spectrometry

被引:32
作者
Cristoni, S
Bernardi, LR
Biunno, I
Guidugli, F
机构
[1] Univ Milan, Ctr Interdisciplinare Studi Biomol & Appl Ind, I-20090 Milan, Italy
[2] ThermoFinnigan Italia SpA, I-20090 Rodano, Milano, Italy
关键词
D O I
10.1002/rcm.772
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel approach, based on the use of atmospheric pressure chemical ionization ion trap mass spectrometry (APCI-ITMS) conditions, but without using corona discharge, was used to analyze peptides. The proposed method was applied to three standard peptides (bombesin, trityrosine and tyrosine-glycine-glycine) as well as peptides obtained through enzymatic digestion of two standard proteins (horse cytochrome c and horse myoglobin). Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:1686 / 1691
页数:6
相关论文
共 41 条
[1]  
Abian J, 1999, J MASS SPECTROM, V34, P157, DOI 10.1002/(SICI)1096-9888(199903)34:3<157::AID-JMS804>3.0.CO
[2]  
2-4
[3]   Comparison of SSI with APCI as an interface of HPLC-mass spectrometry for analysis of a drug and its metabolites [J].
Arinobu, T ;
Hattori, H ;
Seno, H ;
Ishii, A ;
Suzuki, O .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (03) :204-208
[4]   COMBINED LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY .2. TECHNIQUES AND MECHANISMS OF THERMOSPRAY [J].
ARPINO, P .
MASS SPECTROMETRY REVIEWS, 1990, 9 (06) :631-669
[5]  
Barnes S, 1998, P SOC EXP BIOL MED, V217, P254
[6]   THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLAKLEY, CR ;
VESTAL, ML .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :750-754
[7]   ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - CORONA DISCHARGE ION-SOURCE FOR USE IN LIQUID CHROMATOGRAPH MASS SPECTROMETER-COMPUTER ANALYTICAL SYSTEM [J].
CARROLL, DI ;
DZIDIC, I ;
STILLWELL, RN ;
HAEGELE, KD ;
HORNING, EC .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2369-2373
[8]   ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY [J].
CARROLL, DI ;
DZIDIC, I ;
HORNING, EC ;
STILLWELL, RN .
APPLIED SPECTROSCOPY REVIEWS, 1981, 17 (03) :337-406
[9]   Analysis of protein ions in the range 3000-12000 Th under partial (no discharge) atmospheric pressure chemical ionization conditions using ion trap mass spectrometry [J].
Cristoni, S ;
Bernardi, LR ;
Biunno, I ;
Guidugli, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (12) :1153-1159
[10]   Free energy for blue copper protein unfolding determined by electrospray ionisation mass spectrometry [J].