Comparison of SSI with APCI as an interface of HPLC-mass spectrometry for analysis of a drug and its metabolites

被引:23
作者
Arinobu, T
Hattori, H
Seno, H
Ishii, A
Suzuki, O
机构
[1] Aichi Med Univ, Sch Med, Dept Legal Med, Aichi 4801195, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Legal Med & Bioeth, Nagoya, Aichi, Japan
[3] Hamamatsu Univ Sch Med, Dept Legal Med, Hamamatsu, Shizuoka 43131, Japan
关键词
D O I
10.1016/S1044-0305(01)00359-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sonic spray ionization (SSI) was compared with atmospheric pressure chemical ionization (APCI) as an interface of high-performance liquid chromatography (HPLC)-mass spectrometry (MS) for sensitive analyses of a neuroleptic drug, haloperidol and its two metabolites, such as reduced haloperidol and 4-(4-chlorophenyl)-4-hydroxypiperidine (CPHP), in biological samples. For both SSI and APCI interfaces, HPLC-MS-MS gave higher sensitivity than HPLC-MS. The sensitivities by HPLC-SSI-MS-MS for haloperidol and reduced haloperidol were 100 and 30 times higher, respectively, than those by HPLC-APCI-MS-MS; no spectrum with recognizable peaks was obtained for CPHP with the APCI interface. Therefore, detection limits and regression equations were examined by the HPLC-SSI-MS-MS for human plasma and urine samples spiked with the above drug and its metabolites. Haloperidol, reduced haloperidol, and CPHP showed good linearity in the ranges of 5-800, 10-800, and 100-800 ng/mL, respectively, for both human plasma and urine; their detection limits were 2.5, 5, and 75 ng/mL, respectively, using a new polymer HPLC column which enabled direct application of biological samples. (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:204 / 208
页数:5
相关论文
共 11 条
[1]   INVESTIGATION OF THE NEUROLEPTIC DRUG HALOPERIDOL AND ITS METABOLITES USING TANDEM MASS-SPECTROMETRY [J].
FANG, J ;
GORROD, JW ;
KAJBAF, M ;
LAMB, JH ;
NAYLOR, S .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 122 :121-131
[2]  
Hatti-Kaul R, 2000, METH BIOTEC, V11, P1
[3]   'High throughput' solid-phase extraction technology and turbo ionspray LC-MS-MS applied to the determination of haloperidol in human plasma [J].
Hempenius, J ;
Steenvoorden, RJJM ;
Lagerwerf, FM ;
Wieling, J ;
Jonkman, JHG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (06) :889-898
[4]   SONIC SPRAY IONIZATION METHOD FOR ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY [J].
HIRABAYASHI, A ;
SAKAIRI, M ;
KOIZUMI, H .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4557-4559
[5]   SONIC SPRAY MASS-SPECTROMETRY [J].
HIRABAYASHI, A ;
SAKAIRI, M ;
KOIZUMI, H .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2878-2882
[6]   A sonic spray interface for the mass analysis of highly charged ions from protein solutions at high flow rates [J].
Hirabayashi, Y ;
Hirabayashi, A ;
Takada, Y ;
Sakairi, M ;
Koizumi, H .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1882-1884
[7]   Determination of haloperidol and its reduced metabolite in human plasma by liquid chromatography mass spectrometry with electrospray ionization [J].
Hoja, H ;
Marquet, P ;
Verneuil, B ;
Lotfi, H ;
Dupuy, JL ;
Penicaut, B ;
Lachatre, G .
JOURNAL OF CHROMATOGRAPHY B, 1997, 688 (02) :275-280
[8]  
IGARASHI K, 1997, JPN J FORENSIC TOXIC, V15, P44
[9]   Analyses of butyrophenones and their analogues in whole blood by high-performance liquid chromatography-electrospray tandem mass spectrometry [J].
Seno, H ;
Hattori, H ;
Ishii, A ;
Kumazawa, T ;
Watanabe-Suzuki, K ;
Suzuki, O .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 746 (01) :3-9
[10]   Liquid chromatographic thermospray tandem mass spectrometric quantitative analysis of some drugs with hypnotic, sedative and tranquillising properties in whole blood [J].
Verweij, AMA ;
Hordijk, ML ;
Lipman, PJL .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (01) :27-34