A sonic spray interface for the mass analysis of highly charged ions from protein solutions at high flow rates

被引:30
作者
Hirabayashi, Y [1 ]
Hirabayashi, A [1 ]
Takada, Y [1 ]
Sakairi, M [1 ]
Koizumi, H [1 ]
机构
[1] Hitachi Ltd, Cent Res Lab, Kokubunji, Tokyo 1858601, Japan
关键词
D O I
10.1021/ac970872s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have improved the sonic spray interface to enable the analysis of multiply charged ions of protein from a solution at a now rate of 1 mL/min using a conventional liquid chromatograph/mass spectrometer, in this interface, we added a multihole plate in front of the sampling orifice of a mass spectrometer. This plate does not have a hole coaxial to the sampling orifice but has small holes around the central region of the plate. The plate reduces the density of the solvent molecules in the sprayed gas introduced into the vacuum region through the sampling orifice from the atmosphere and prevents the ions from being solvated and becoming charged droplets due to the cooling that follows adiabatic expansion of the sprayed gas. With this improvement, multiply charged ions whose charge distribution ranged from 11+ to 16+ were analyzed from a 1 mu M cytochrome c solution at a high flow rate of 1 mL/min without using a splitter.
引用
收藏
页码:1882 / 1884
页数:3
相关论文
共 20 条
[1]   THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLAKLEY, CR ;
VESTAL, ML .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :750-754
[2]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[3]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[4]  
Hirabayashi A, 1996, RAPID COMMUN MASS SP, V10, P1703, DOI 10.1002/(SICI)1097-0231(199610)10:13<1703::AID-RCM687>3.0.CO
[5]  
2-J
[6]   SONIC SPRAY IONIZATION METHOD FOR ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY [J].
HIRABAYASHI, A ;
SAKAIRI, M ;
KOIZUMI, H .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4557-4559
[7]   ION MOLECULE REACTION AND ION EVAPORATION IN ATMOSPHERIC-PRESSURE SPRAY IONIZATION [J].
HIRABAYASHI, A ;
TAKADA, Y ;
KAMBARA, H ;
UMEMURA, Y ;
OHTA, H ;
ITO, H ;
KUCHITSU, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 120 (03) :207-216
[8]   SONIC SPRAY MASS-SPECTROMETRY [J].
HIRABAYASHI, A ;
SAKAIRI, M ;
KOIZUMI, H .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2878-2882
[9]  
HIRABAYASHI A, 1993, J MASS SPECTROM SOC, V41, P287
[10]  
Hirabayashi Y, 1996, RAPID COMMUN MASS SP, V10, P1891, DOI 10.1002/(SICI)1097-0231(199612)10:15<1891::AID-RCM722>3.0.CO