Ultra high-resolution fMRI in monkeys with implanted RF coils

被引:121
作者
Logothetis, NK
Merkle, H
Augath, M
Trinath, T
Ugurbil, K
机构
[1] Max Planck Inst Biol Cybernet, D-72076 Tubingen, Germany
[2] Univ Minnesota, Dept Radiol, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
D O I
10.1016/S0896-6273(02)00775-4
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Spatiotemporally resolved functional MRI (fMRI) in animals can reveal how wide-spread neural networks are organized and accompanying electrophysiological recordings can show how small neural assemblies contribute to this organization. Here we present a novel technique that yields high-resolution structural and functional images of the monkey brain with small, tissue-compatible, intraosteally implantable radiofrequency coils. Voxel sizes as small as 0.0113 mul with high signal-to-noise and contrast-to-noise ratios were obtained, revealing both structural and functional cortical architecture in great detail. Up to a certain point, contrast sensitivity increased with decreasing voxel size, probably because of the decreased partial volume effects. Spatial specificity was demonstrated by the lamina-specific activation in experiments comparing responses to moving and flickering stimuli. The implications of this technique for combined fMRI/electrophysiology experiments and its limitations in terms of spatial coverage are discussed.
引用
收藏
页码:227 / 242
页数:16
相关论文
共 84 条
  • [1] DIRECTION AND ORIENTATION SELECTIVITY OF NEURONS IN VISUAL AREA MT OF THE MACAQUE
    ALBRIGHT, TD
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 1984, 52 (06) : 1106 - 1130
  • [2] TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION
    BANDETTINI, PA
    WONG, EC
    HINKS, RS
    TIKOFSKY, RS
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 390 - 397
  • [3] PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN
    BANDETTINI, PA
    JESMANOWICZ, A
    WONG, EC
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 161 - 173
  • [4] SURFACE MODIFICATION OF TITANIUM-ALLOY IMPLANTS
    BROWNE, M
    GREGSON, PJ
    [J]. BIOMATERIALS, 1994, 15 (11) : 894 - 898
  • [5] INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    THOMPSON, RM
    JACK, CR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) : 67 - 72
  • [6] Human ocular dominance columns as revealed by high-field functional magnetic resonance imaging
    Cheng, K
    Waggoner, RA
    Tanaka, K
    [J]. NEURON, 2001, 32 (02) : 359 - 374
  • [7] INVIVO MYELOARCHITECTONIC ANALYSIS OF HUMAN STRIATE AND EXTRASTRIATE CORTEX USING MAGNETIC-RESONANCE-IMAGING
    CLARK, VP
    COURCHESNE, E
    GRAFE, M
    [J]. CEREBRAL CORTEX, 1992, 2 (05) : 417 - 424
  • [8] Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible
    Cochran, DL
    Hermann, JS
    Schenk, RK
    Higginbottom, FL
    Buser, D
    [J]. JOURNAL OF PERIODONTOLOGY, 1997, 68 (02) : 186 - 197
  • [9] Cochran DL, 1998, J BIOMED MATER RES, V40, P1, DOI 10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO
  • [10] 2-Q