OBJECTIVE. The purpose of this study was to assess the potential of active biplanar MR needle tracking in a 0.5-T open-configuration MR system. A needle design characterized by an integrated internal signal source was used. To evaluate the performance of this new technique in vivo as well as in vitro, procedures were performed on patients. CONCLUSION. The results of this study prove that the biplanar tracking concept can be applied in a clinical environment. The applicability of biplanar tracking is further enhanced by integrating an internal signal source.
引用
收藏
页码:735 / 738
页数:4
相关论文
共 11 条
[1]  
ALBERT K, 1994, BIO-MED MATER ENG, V4, P199
[2]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415
[3]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[4]   SIMULTANEOUS TEMPORAL RESOLUTION OF CARDIAC AND RESPIRATORY MOTION IN MR-IMAGING [J].
FREDRICKSON, JO ;
WEGMULLER, H ;
HERFKENS, RJ ;
PELC, NJ .
RADIOLOGY, 1995, 195 (01) :169-175
[5]   INTRAVASCULAR MR TRACKING CATHETER - PRELIMINARY EXPERIMENTAL EVALUATION [J].
LEUNG, DA ;
DEBATIN, JF ;
WILDERMUTH, S ;
MCKINNON, GC ;
HOLTZ, D ;
DUMOULIN, CL ;
DARROW, RD ;
HOFMANN, E ;
VONSCHULTHESS, GK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1265-1270
[6]   REAL-TIME BIPLANAR NEEDLE TRACKING FOR INTERVENTIONAL MR-IMAGING PROCEDURES [J].
LEUNG, DA ;
DEBATIN, JF ;
WILDERMUTH, S ;
HESKE, N ;
DUMOULIN, CL ;
DARROW, RD ;
HAUSER, M ;
DAVIS, CP ;
VONSCHULTHESS, GK .
RADIOLOGY, 1995, 197 (02) :485-488
[7]   A TECHNIQUE FOR MR-GUIDED NEEDLE PLACEMENT [J].
LUFKIN, R ;
TERESI, L ;
CHIU, L ;
HANAFEE, W .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (01) :193-196
[8]   MR BODY STEREOTAXIS - AN AID FOR MR-GUIDED BIOPSIES [J].
LUFKIN, R ;
DUCKWILER, G ;
SPICKLER, E ;
TERESI, L ;
CHANG, M ;
ONIK, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (06) :1088-1089
[9]  
MAIER SE, 1995, SOC MAGNETIC RESONAN, P497
[10]   SUPERCONDUCTING OPEN-CONFIGURATION MR-IMAGING SYSTEM FOR IMAGE-GUIDED THERAPY [J].
SCHENCK, JF ;
JOLESZ, FA ;
ROEMER, PB ;
CLINE, HE ;
LORENSEN, WE ;
KIKINIS, R ;
SILVERMAN, SG ;
HARDY, CJ ;
BARBER, WD ;
LASKARIS, ET ;
DORRI, B ;
NEWMAN, RW ;
HOLLEY, CE ;
COLLICK, BD ;
DIETZ, DP ;
MACK, DC ;
AINSLIE, MD ;
JASKOLSKI, PL ;
FIGUEIRA, MR ;
LEHN, JCV ;
SOUZA, SP ;
DUMOULIN, CL ;
DARROW, RD ;
STPETERS, RL ;
ROHLING, KW ;
WATKINS, RD ;
EISNER, DR ;
BLUMENFELD, SM ;
VOSBURGH, KG .
RADIOLOGY, 1995, 195 (03) :805-814