Pathology of Second-Generation Everolimus-Eluting Stents Versus First-Generation Sirolimus- and Paclitaxel-Eluting Stents in Humans

被引:421
作者
Otsuka, Fumiyuki [1 ]
Vorpahl, Marc [1 ]
Nakano, Masataka [1 ]
Foerst, Jason [2 ]
Newell, John B. [3 ]
Sakakura, Kenichi [1 ]
Kutys, Robert [1 ]
Ladich, Elena [1 ]
Finn, Aloke V. [4 ]
Kolodgie, Frank D. [1 ]
Virmani, Renu [1 ]
机构
[1] CVPath Inst Inc, Gaithersburg, MD 20878 USA
[2] Virginia Tech, Carilion Sch Med, Roanoke, VA USA
[3] Partners Hlth Care Syst, Boston, MA USA
[4] Emory Univ, Sch Med, Atlanta, GA USA
关键词
coronary restenosis; pathology; stents; thrombosis; PERCUTANEOUS CORONARY INTERVENTION; RANDOMIZED CONTROLLED-TRIAL; BARE-METAL; CLINICAL-EVALUATION; FOLLOW-UP; THROMBOSIS; IMPLANTATION; FRACTURE; OUTCOMES; ENDOTHELIALIZATION;
D O I
10.1161/CIRCULATIONAHA.113.001790
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Clinical trials have demonstrated that the second-generation cobalt-chromium everolimus-eluting stent (CoCr-EES) is superior to the first-generation paclitaxel-eluting stent (PES) and is noninferior or superior to the sirolimus-eluting stent (SES) in terms of safety and efficacy. It remains unclear whether vascular responses to CoCr-EES are different from those to SES and PES because the pathology of CoCr-EES has not been described in humans. Methods and Results A total of 204 lesions (SES=73; PES=85; CoCr-EES=46) from 149 autopsy cases with duration of implantation >30 days and 3 years were pathologically analyzed, and comparison of vascular responses was corrected for duration of implantation. The observed frequency of late and very late stent thrombosis was less in CoCr-EES (4%) versus SES (21%; P=0.029) and PES (26%; P=0.008). Neointimal thickness was comparable among the groups, whereas the percentage of uncovered struts was strikingly lower in CoCr-EES (median=2.6%) versus SES (18.0%; P<0.0005) and PES (18.7%; P<0.0005). CoCr-EES showed a lower inflammation score (with no hypersensitivity) and less fibrin deposition versus SES and PES. The observed frequency of neoatherosclerosis, however, did not differ significantly among the groups (CoCr-EES=29%; SES=35%; PES=19%). CoCr-EES had the least frequency of stent fracture (CoCr-EES=13%; SES=40%; PES=19%; P=0.007 for CoCr-EES versus SES), whereas fracture-related restenosis or thrombosis was comparable among the groups (CoCr-EES=6.5%; SES=5.5%; PES=1.2%). Conclusions CoCr-EES demonstrated greater strut coverage with less inflammation, less fibrin deposition, and less late and very late stent thrombosis compared with SES and PES in human autopsy analysis. Nevertheless, the observed frequencies of neoatherosclerosis and fracture-related adverse pathological events were comparable in these devices, indicating that careful long-term follow-up remains important even after CoCr-EES placement.
引用
收藏
页码:211 / 223
页数:13
相关论文
共 31 条
[1]   Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation [J].
Awata, Masaki ;
Kotani, Jun-ichi ;
Uematsu, Masaaki ;
Morozumi, Takakazu ;
Watanabe, Tetsuya ;
Onishi, Toshinari ;
Iida, Osamu ;
Sera, Fusako ;
Nanto, Shinsuke ;
Hori, Masatsugu ;
Nagata, Seiki .
CIRCULATION, 2007, 116 (08) :910-916
[2]   Short- and Long-Term Outcomes With Drug-Eluting and Bare-Metal Coronary Stents A Mixed-Treatment Comparison Analysis of 117 762 Patient-Years of Follow-Up From Randomized Trials [J].
Bangalore, Sripal ;
Kumar, Sunil ;
Fusaro, Mario ;
Amoroso, Nicholas ;
Attubato, Michael J. ;
Feit, Frederick ;
Bhatt, Deepak L. ;
Slater, James .
CIRCULATION, 2012, 125 (23) :2873-+
[3]   Impact of Lesion Length and Vessel Size on Clinical Outcomes After Percutaneous Coronary Intervention With Everolimus- Versus Paclitaxel-Eluting Stents Pooled Analysis From the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials [J].
Claessen, Bimmer E. ;
Smits, Pieter C. ;
Kereiakes, Dean J. ;
Parise, Helen ;
Fahy, Martin ;
Kedhi, Elvin ;
Serruys, Patrick W. ;
Lansky, Alexandra J. ;
Cristea, Ecaterina ;
Sudhir, Krishnankutty ;
Sood, Poornima ;
Simonton, Charles A. ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (11) :1209-1215
[4]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[5]   Pathological analysis of local delivery of paclitaxel via a polymer-coated stent [J].
Farb, A ;
Heller, PF ;
Shroff, S ;
Cheng, L ;
Kolodgie, FD ;
Carter, AJ ;
Scott, DS ;
Froehlich, J ;
Virmani, R .
CIRCULATION, 2001, 104 (04) :473-479
[6]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[7]   Optical coherence evaluation of everolimus-eluting stents 8 months after implantation [J].
Inoue, Takumi ;
Shite, Junya ;
Yoon, Junghan ;
Shinke, Toshiro ;
Otake, Hiromasa ;
Sawada, Takahiro ;
Kawamori, Hiroyuki ;
Katoh, Hiroki ;
Miyoshi, Naoki ;
Yoshino, Naoki ;
Kozuki, Amane ;
Hariki, Hirotoshi ;
Hirata, Ken-ichi .
HEART, 2011, 97 (17) :1379-1384
[8]   Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated With Percutaneous Coronary Intervention The Scandinavian Organization for Randomized Trials With Clinical Outcome IV (SORT OUT IV) [J].
Jensen, Lisette Okkels ;
Thayssen, Per ;
Hansen, Henrik Steen ;
Christiansen, Evald Hoj ;
Tilsted, Hans Henrik ;
Krusell, Lars Romer ;
Villadsen, Anton Boel ;
Junker, Anders ;
Hansen, Knud Norregaard ;
Kaltoft, Anne ;
Maeng, Michael ;
Pedersen, Knud Erik ;
Kristensen, Steen Dalby ;
Botker, Hans Erik ;
Ravkilde, Jan ;
Sanchez, Richardo ;
Aaroe, Jens ;
Madsen, Morten ;
Sorensen, Henrik Toft ;
Thuesen, Leif ;
Lassen, Jens Flensted .
CIRCULATION, 2012, 125 (10) :1246-1255
[9]   Endothelial cell recovery between comparator polymer-based drug-eluting stents [J].
Joner, Michael ;
Nakazawa, Gaku ;
Finn, Aloke V. ;
Quee, Shawn Chin ;
Coleman, Leslie ;
Acampado, Eduardo ;
Wilson, Patricia S. ;
Skorija, Kristi ;
Cheng, Qi ;
Xu, Xin ;
Gold, Herman K. ;
Kolodgie, Frank D. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (05) :333-342
[10]   Long-Term Comparison of Everolimus- and Sirolimus-Eluting Stents in Patients With Acute Coronary Syndromes [J].
Kalesan, Bindu ;
Stefanini, Giulio G. ;
Raeber, Lorenz ;
Schmutz, Mathieu ;
Baumgartner, Sandro ;
Hitz, Sarah ;
Baldinger, Samuel H. ;
Pilgrim, Thomas ;
Moschovitis, Aris ;
Wenaweser, Peter ;
Buellesfeld, Lutz ;
Khattab, Ahmed A. ;
Meier, Bernhard ;
Jueni, Peter ;
Windecker, Stephan .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (02) :145-154