Motor-unit synchronization increases EMG amplitude and decreases force steadiness of simulated contractions

被引:355
作者
Yao, WX
Fuglevand, AJ
Enoka, RM [1 ]
机构
[1] Univ Colorado, Dept Kinesiol & Appl Physiol, Boulder, CO 80309 USA
[2] Univ Arizona, Dept Physiol, Tucson, AZ 85721 USA
关键词
D O I
10.1152/jn.2000.83.1.441
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of the study was to determine the effect of motor-unit synchronization on the surface electromyogram (EMG) and isometric force using a computer model of muscle contraction. The EMG and force were simulated by generating muscle fiber action potentials, defining motor-unit mechanical characteristics and territories, estimating motor-unit action potentials, specifying motor-unit discharge times, and imposing various levels of motor-unit synchronization. The output (EMG and force) was simulated at 11 levels of excitation, ranging from 5 to 100% of maximum. To synchronize motor-unit activity, selected motor-unit discharge times were adjusted; however, the number of motor units recruited and the average discharge rate of each unit was constant across synchronization conditions for a given level of excitation. Two levels of synchronization were imposed on the discharge times: a moderate and a high level, which approximated the experimentally observed range of motor-unit synchronization. The moderate level of synchrony caused the average EMG to increase by similar to 65%, whereas the high level caused a 130% increase in the EMG with respect to the no-synchrony condition. Neither synchrony condition influenced the magnitude of the average force. However, motor-unit synchronization did increase the amplitude of the fluctuations in the simulated force, especially at intermediate levels of excitation. In conclusion, motor-unit synchronization increased the amplitude of the average rectified EMG and decreased the steadiness of the force exerted by the muscle in simulated contractions.
引用
收藏
页码:441 / 452
页数:12
相关论文
共 68 条
[41]   CHANGES IN FIRING RATE OF HUMAN MOTOR UNITS DURING LINEARLY CHANGING VOLUNTARY CONTRACTIONS [J].
MILNERBR.HS ;
STEIN, RB ;
YEMM, R .
JOURNAL OF PHYSIOLOGY-LONDON, 1973, 230 (02) :371-390
[42]   SYNCHRONIZATION OF HUMAN MOTOR UNITS - POSSIBLE ROLES OF EXERCISE AND SUPRASPINAL REFLEXES [J].
MILNERBROWN, HS ;
STEIN, RB ;
LEE, RG .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 38 (03) :245-254
[43]   RELATION BETWEEN SURFACE ELECTROMYOGRAM AND MUSCULAR FORCE [J].
MILNERBROWN, HS ;
STEIN, RB .
JOURNAL OF PHYSIOLOGY-LONDON, 1975, 246 (03) :549-569
[44]   ISOMETRIC FORCE PRODUCTION BY MOTOR UNITS OF EXTENSOR DIGITORUM COMMUNIS MUSCLE IN MAN [J].
MONSTER, AW ;
CHAN, H .
JOURNAL OF NEUROPHYSIOLOGY, 1977, 40 (06) :1432-1443
[45]   ESTIMATING THE STRENGTH OF COMMON INPUT TO HUMAN MOTONEURONS FROM THE CROSS-CORRELOGRAM [J].
NORDSTROM, MA ;
FUGLEVAND, AJ ;
ENOKA, RM .
JOURNAL OF PHYSIOLOGY-LONDON, 1992, 453 :547-574
[46]   SUMMATION OF MOTOR UNIT TENSIONS IN THE TIBIALIS POSTERIOR MUSCLE OF THE CAT UNDER ISOMETRIC AND NONISOMETRIC CONDITIONS [J].
POWERS, RK ;
BINDER, MD .
JOURNAL OF NEUROPHYSIOLOGY, 1991, 66 (06) :1838-1846
[47]   DISTRIBUTION OF OLIGOSYNAPTIC GROUP-I INPUT TO THE CAT MEDIAL GASTROCNEMIUS MOTONEURON POOL [J].
POWERS, RK ;
BINDER, MD .
JOURNAL OF NEUROPHYSIOLOGY, 1985, 53 (02) :497-517
[48]   EFFECTS OF LENGTH AND STIMULUS RATE ON TENSION IN ISOMETRIC CAT SOLEUS MUSCLE [J].
RACK, PMH ;
WESTBURY, DR .
JOURNAL OF PHYSIOLOGY-LONDON, 1969, 204 (02) :443-+
[49]   Motor unit potential contribution to surface electromyography [J].
Roeleveld, K ;
Stegeman, DF ;
Vingerhoets, HM ;
vanOosterom, A .
ACTA PHYSIOLOGICA SCANDINAVICA, 1997, 160 (02) :175-183
[50]  
Schmied A., 1998, Society for Neuroscience Abstracts, V24, P424