Applicability of mass spectrometry to detect coeluting impurities in high-performance liquid chromatography

被引:8
作者
Antonovich, RS [1 ]
Keller, PR [1 ]
机构
[1] Procter & Gamble Pharmaceut, Norwich, NY 13815 USA
关键词
pharmaceutical analysis; peak purity; azimilide; aminosalicylic acid; digoxin; digitoxin;
D O I
10.1016/S0021-9673(02)01004-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An array of pharmaceutical compounds and impurities were used to investigate the applicability of atmospheric pressure ionization mass spectrometry (MS) to routinely detect coeluting impurities in HPLC (i.e. peak purity). Four drugs were individually tested against their related impurity set using a straightforward HPLC-MS peak purity strategy. For the investigated set, which represents 24 unique drug-impurity permutations, 75% of the coeluting impurities were detected at levels <1.0%, including one-third at 0.1% (%, w/w). Factors that affect the applicability of this peak purity approach are also discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:159 / 171
页数:13
相关论文
共 30 条
[1]   Determination of liquid chromatographic peak purity by electrospray ionization mass spectrometry [J].
Bryant, DK ;
Kingswood, MD ;
Belenguer, A .
JOURNAL OF CHROMATOGRAPHY A, 1996, 721 (01) :41-51
[2]   Peak purity assessment in liquid chromatography-mass spectrometry [J].
Bylund, D ;
Danielsson, R ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 2001, 915 (1-2) :43-52
[3]   STRATEGIES FOR PEAK-PURITY ASSESSMENT IN LIQUID-CHROMATOGRAPHY [J].
CASTLEDINE, JB ;
FELL, AF .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (01) :1-13
[4]  
Ermer J, 2000, BIOMED CHROMATOGR, V14, P373, DOI 10.1002/1099-0801(200010)14:6<373::AID-BMC29>3.0.CO
[5]  
2-S
[6]   EVALUATION OF DIFFERENT TECHNIQUES FOR PEAK PURITY ASSESSMENT ON A DIODE-ARRAY DETECTOR IN LIQUID-CHROMATOGRAPHY [J].
FABRE, H ;
LEBRIS, A ;
BLANCHIN, MD .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :81-88
[7]   Chiral capillary electrophoresis electrospray mass spectrometry coupling using vancomycin as chiral selector [J].
Fanali, S ;
Desiderio, C ;
Schulte, G ;
Heitmeier, S ;
Strickmann, D ;
Chankvetadze, B ;
Blaschke, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 800 (01) :69-76
[8]  
FISHER D, 1996, 44 ASMS C MS ALL TOP
[9]  
GRUNDNER E, 2001, COMMUNICATION
[10]   Use of an ion-pairing reagent for high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry determination of anionic anticoagulant rodenticides in body fluids [J].
Guan, FY ;
Ishii, A ;
Seno, H ;
Watanabe-Suzuki, K ;
Kumazawa, T ;
Suzuki, O .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 731 (01) :155-165