Renewable Protein A modified graphite-epoxy composite for electrochemical immunosensing

被引:34
作者
Zacco, E
Pividori, MI
Llopis, X
del Valle, M
Alegret, S [1 ]
机构
[1] Univ Autonoma Barcelona, Dept Quim, Grp Senisors & Biosensors, Bellaterra 08193, Catalonia, Spain
[2] Univ Nacl Litoral, Fac Bioquim & Ciencias Biol, Santa Fe, Argentina
关键词
graphite-epoxy composites; protein A; enzyme label; electrochemical immunosensor; immunoassay; biocomposite;
D O I
10.1016/j.jim.2003.11.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel rigid and renewable transducing material for electrochemical immunosensing, based on Protein A bulk-modified,graphite-epoxy biocomposite (ProtA-GEB) is reported. Protein A is able to bind to the Fc region of antibodies and provide an affinity matrix for antibody immobilisation onto the transducer. The rigid conducting biocomposite acts not only as a transducer, but also as a reservoir for protein A. After use, the electrode surface can be renewed by a simple polishing procedure, highlighting a clear advantage of this new approach with respect to classical immunoassays. The performance of ProtA-GEB transducers was compared with surface-modified transducers based on a simple dry adsorption procedure, where both Protein A and directly the antibody were adsorbed onto the surface of graphite-epoxy composite (ProtA/GEC and IgG/GEC, respectively). The application of the new biocomposite material in electrochemical immunosensing was studied using a model competitive immunoassay. The immunological reaction was detected using an enzymatic-labeling procedure together with the amperometric detection through a suitable substrate (H(2)O(2)) for the enzyme (HRP). The enzymatic labelling was performed using a two-step procedure based on the biotin/streptavidin interaction as well as a one-step procedure using an antibody labelled with the enzyme. Electrochemical and microscopic characterisation of ProtA-GEB transducer, optimisation of the immunosensor design as well as the stability of this material are also reported. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 46
页数:12
相关论文
共 22 条
[1]   Rigid carbon - Polymer biocomposites for electrochemical sensing - A review [J].
Alegret, S .
ANALYST, 1996, 121 (12) :1751-1758
[2]  
Alegret S, 1996, SENSOR MATER, V8, P147
[3]  
ALEGRET S, 2003, INTEGRATED ANAL SYST, P17
[4]   New materials for electrochemical sensing .1. Rigid conducting composites [J].
Cespedes, F ;
MartinezFabregas, E ;
Alegret, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) :296-304
[5]   ANALYTICAL POTENTIAL OF PROTEIN-A FOR AFFINITY-CHROMATOGRAPHY OF POLYCLONAL AND MONOCLONAL-ANTIBODIES [J].
COMPTON, BJ ;
LEWIS, M ;
WHIGHAM, F ;
GERALD, JS ;
COUNTRYMAN, GE .
ANALYTICAL CHEMISTRY, 1989, 61 (13) :1314-1317
[6]   RAPID HETEROGENEOUS COMPETITIVE ELECTROCHEMICAL IMMUNOASSAY FOR IGG IN THE PICOMOLE RANGE [J].
DEALWIS, U ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2786-2789
[7]   Development of an electrochemical flow injection immunoassay (FIIA) for the real-time monitoring of biospecific interactions [J].
Killard, AJ ;
Zhang, SQ ;
Zhao, HJ ;
John, R ;
Iwuoha, EI ;
Smyth, MR .
ANALYTICA CHIMICA ACTA, 1999, 400 :109-119
[8]   Amperometric immunosensors based on protein A coupled polyaniline-perfluorosulfonated ionomer composite electrodes [J].
Liu, CH ;
Liao, KT ;
Huang, HJ .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2925-2929
[9]   A reusable and specific protein A-coated piezoelectric biosensor for flow injection immunoassay [J].
Lu, HC ;
Chen, HM ;
Lin, YS ;
Lin, JW .
BIOTECHNOLOGY PROGRESS, 2000, 16 (01) :116-124
[10]   AMPEROMETRIC DETERMINATION OF PESTICIDES USING A BIOSENSOR BASED ON A POLISHABLE GRAPHITE-EPOXY BIOCOMPOSITE [J].
MARTORELL, D ;
CESPEDES, F ;
MARTINEZFABREGAS, E ;
ALEGRET, S .
ANALYTICA CHIMICA ACTA, 1994, 290 (03) :343-348