Computational Hemodynamics Analysis of Intracranial Aneurysms Treated with Flow Diverters: Correlation with Clinical Outcomes

被引:86
作者
Chong, W. [1 ]
Zhang, Y. [2 ]
Qian, Y. [2 ]
Lai, L. [2 ]
Parker, G. [3 ]
Mitchell, K. [4 ]
机构
[1] Monash Med Ctr, Melbourne, Vic, Australia
[2] Macquarie Univ, Australian Sch Adv Med, N Ryde, NSW 2109, Australia
[3] Royal Prince Alfred Hosp, Sydney, NSW, Australia
[4] Royal Brisbane Hosp, Brisbane, Qld 4029, Australia
基金
澳大利亚研究理事会;
关键词
CEREBRAL ANEURYSM; SUBJECT; RUPTURE; STENTS;
D O I
10.3174/ajnr.A3790
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
BACKGROUND AND PURPOSE: Recent studies have shown promising results regarding intracranial aneurysms treated with flow diverters. However, these have had adverse effects, including delayed aneurysm occlusion, posttreatment symptoms, and rupture. The hemodynamic profiles of aneurysms treated with flow diverters were analyzed to determine the ones associated with successful and failed treatments. MATERIALS AND METHODS: Patient-specific computational fluid dynamics were used to simulate hemodynamic profiles, including the presence of jet flow, energy loss, volume flow, and wall shear stress in 4 successful occlusions of aneurysms and 4 failed cases after flow-diverter deployment. In these 4 failed cases, hemodynamic profiles were examined again after a hypothetic second intervention. This involved replacing the failed flow diverter with a hypothetic optimally deployed flow diverter or simulated placement of a second flow diverter within the first (double hypothetic optimally deployed). RESULTS: Where successful occlusions were achieved, a marked obliteration of jet flow was observed. Flow entering the aneurysm sac was diverted via the center of the flow diverter and joined smoothly with the continuation of flow leaving the aneurysm sac into the parent arteries. These observations were supplemented by a reduction in the other hemodynamic profiles. Aneurysm neck geometry might influence the efficacy of the flow diverter. CONCLUSIONS: Hemodynamic indices, as calculated by using computational fluid dynamics techniques, have close correlation with flow-diverter treatment outcome. Computational fluid dynamics could be potentially useful as a planning tool for neurointerventionists by simulating an optimized flow-diverter deployment strategy before the procedure and evaluating posttreatment outcome.
引用
收藏
页码:136 / 142
页数:7
相关论文
共 16 条
[1]
Akpek S, 2005, AM J NEURORADIOL, V26, P1223
[2]
Computational fluid dynamics of stented intracranial aneurysms using adaptive embedded unstructured grids [J].
Appanaboyina, S. ;
Mut, F. ;
Lohner, R. ;
Putman, C. A. ;
Cebral, J. R. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2008, 57 (05) :475-493
[3]
Intracranial Stents Being Modeled as a Porous Medium: Flow Simulation in Stented Cerebral Aneurysms [J].
Augsburger, L. ;
Reymond, P. ;
Rufenacht, D. A. ;
Stergiopulos, N. .
ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (02) :850-863
[4]
Early Experience in the Treatment of Intra-Cranial Aneurysms by Endovascular Flow Diversion: A Multicentre Prospective Study [J].
Byrne, James V. ;
Beltechi, Radu ;
Yarnold, Julia A. ;
Birks, Jacqueline ;
Kamran, Mudassar .
PLOS ONE, 2010, 5 (09) :1-8
[5]
Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment [J].
Cebral, J. R. ;
Mut, F. ;
Raschi, M. ;
Scrivano, E. ;
Ceratto, R. ;
Lylyk, P. ;
Putman, C. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :27-33
[6]
Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment [J].
Kulcsar, Z. ;
Houdart, E. ;
Bonafe, A. ;
Parker, G. ;
Millar, J. ;
Goddard, A. J. P. ;
Renowden, S. ;
Gal, G. ;
Turowski, B. ;
Mitchell, K. ;
Gray, F. ;
Rodriguez, M. ;
van den Berg, R. ;
Gruber, A. ;
Desal, H. ;
Wanke, I. ;
Ruefenacht, D. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :20-25
[7]
CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE: THE BUENOS AIRES EXPERIENCE [J].
Lylyk, Pedro ;
Miranda, Carlos ;
Ceratto, Rosana ;
Ferrario, Angel ;
Scrivano, Esteban ;
Luna, Hugh Ramirez ;
Berez, Aaron L. ;
Tran, Quang ;
Nelson, Peter K. ;
Fiorella, David .
NEUROSURGERY, 2009, 64 (04) :632-642
[8]
Meng H, 2006, AM J NEURORADIOL, V27, P1861
[9]
Molyneux AJ, 2004, AM J NEURORADIOL, V25, P39
[10]
Qian Y, 2008, STROKE, V39, P646