Speciation of dissolved iron(III) and iron(II) in water by on-line coupling of flow injection separation and preconcentration with inductively coupled plasma mass spectrometry

被引:98
作者
Yan, XP [1 ]
Hendry, NJ
Kerrich, R
机构
[1] Nankai Univ, Dept Chem, Tianjin 300071, Peoples R China
[2] Univ Saskatchewan, Dept Geol Sci, Saskatoon, SK S7N 5E2, Canada
关键词
D O I
10.1021/ac9909655
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method has been developed for the speciation of trace dissolved Fe(III) and Fe(II) in water by on-line coupling of now injection separation and preconcentration with inductively coupled plasma mass spectrometry (ICPMS), Selective determination of Fe(III) in the presence of Fe(II) was made possible by on-line formation and sorption of the Fe(III)-pyrrolidinecarbodithioate (PDC) complex in a PTFE knotted reactor over a sample acidity range of 0.07-0.4 mol L-1 HCl, eiution with 1 mol L-1 HNO3, and detection by ICPMS, Over a sample acidity range of 0.001-0.004 mol L-1 HCl, the sum of Fe(III) and Fe(II), i.e., Fe(III + II), could be determined without the need for preoxidation of Fe(II) to Fe(III), The concentration of Fe(II) was obtained as the difference between those of Fe(III + II) and Fe(III), With a sample flow rate of 5 mL min(-1) and a 30-s preconcentration time, an enhancement factor of 12, a retention efficiency of 80%, and a detection limit (3s) of 0.08 mu g L-1 were obtained at a sampling frequency of 21 samples h(-1). The relative standard deviation (n = 11) was 2.9% at;the 10 mu g L-1 Fe(III) level. Recoveries of spiked Fe(III) and Fe(II) in local tap water, river water, and groundwater samples ranged from 95% to 103%. The concentrations of Fe(III) and Fe(II) in synthetic aqueous mixtures obtained by the proposed method were in good agreement with the spiked values. The result for total iron concentration in the river water reference material SLRS-3 was in good agreement with the certified value. The method was successfully applied to the determination of trace dissolved Fe(III) and Fe(II) in local tap water, river water, and groundwater samples.
引用
收藏
页码:1879 / 1884
页数:6
相关论文
共 47 条
[1]   RAPID FLOW-ANALYSIS WITH INDUCTIVELY COUPLED PLASMA ATOMIC-EMISSION SPECTROSCOPY USING A MICRO-INJECTION TECHNIQUE [J].
ALEXANDER, PW ;
FINLAYSON, RJ ;
SMYTHE, LE ;
THALIB, A .
ANALYST, 1982, 107 (1280) :1335-1342
[2]   SAMPLE WORK-UP FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY USING CONTINUOUS-FLOW EXTRACTION [J].
BACKSTROM, K ;
DANIELSSON, LG ;
NORD, L .
ANALYST, 1984, 109 :323-325
[3]   INJECTION METHOD FOR THE SEQUENTIAL DETERMINATION OF BORON AND SEVERAL METALS IN WASTEWATER SAMPLES BY INDUCTIVELY-COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY [J].
BROEKAERT, JAC ;
LEIS, F .
ANALYTICA CHIMICA ACTA, 1979, 109 (01) :73-83
[4]   METAL-ION SULFUR(IV) CHEMISTRY .3. THERMODYNAMICS AND KINETICS OF TRANSIENT IRON(III) SULFUR(IV) COMPLEXES [J].
CONKLIN, MH ;
HOFFMANN, MR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1988, 22 (08) :899-907
[5]  
Cotton F. A., 1998, ADV INORG CHEM, P868
[6]   FIELD SAMPLING TECHNIQUE FOR SPECIATION OF INORGANIC CHROMIUM IN RIVERS [J].
COX, AG ;
MCLEOD, CW .
MIKROCHIMICA ACTA, 1992, 109 (1-4) :161-164
[7]   DETERMINATION OF IRON(II) AND IRON(III) BY FLOW-INJECTION AND AMPEROMETRIC DETECTION WITH A GLASSY-CARBON ELECTRODE [J].
DIEKER, JW ;
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :267-274
[8]  
Fang Z., 1995, FLOW INJECTION ATOMI
[9]   DETERMINATION OF CADMIUM IN BIOLOGICAL-MATERIALS BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH FLOW-INJECTION ONLINE SORPTION PRECONCENTRATION [J].
FANG, ZL ;
XU, SK ;
DONG, LP ;
LI, WQ .
TALANTA, 1994, 41 (12) :2165-2172
[10]  
Greenberg A. E., 1992, STANDARD METHODS EXA