Statistics of single-molecule measurements: Applications in flow-cytometry sizing of DNA fragments

被引:17
作者
Ferris, MM
Habbersett, RC
Wolinsky, M
Jett, JH
Yoshida, TM
Keller, RA
机构
[1] Los Alamos Natl Lab, Biosci Div, Los Alamos, NM 87545 USA
[2] Los Alamos Natl Lab, Div Chem, Los Alamos, NM 87545 USA
关键词
flow cytometry; single molecule; SMD; Monte Carlo; statistics; DNA;
D O I
10.1002/cyto.a.20000
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: The measurement of physical properties from single molecules has been demonstrated. However, the majority of single-molecule studies report values based on relatively large data sets (e.g., N > 50). While there are studies that report physical quantities based on small sample sets, there has not been a detailed statistical analysis relating sample size to the reliability of derived parameters. Methods: Monte Carlo simulations and multinomial analysis, dependent on quantifiable experimental parameters, were used to determine the minimum number of Single-molecule measurements required to produce an accurate estimate of a population mean. Simulation results were applied to the fluorescence-based sizing of DNA fragments by ultrasensitive flow cytometry (FCM). Results: Our simulations show, for an analytical technique with a 10% CV, that the average of as few as five single-molecule measurements would provide a mean value within one SD of the population mean. Additional simulations determined the number of measurements required to obtain the desired number of replicates for each subpopulation within a mixture. Application of these results to flow cytometry data for lambda/HindIII and S. aureus Mu50/SmaI DNA digests produced accurate DNA fingerprints from as few as 98 single-molecule measurements. Conclusions: A surprisingly small number of single-molecule measurements are required to obtain a mean measurement descriptive of a normally-distributed parent population. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:41 / 52
页数:12
相关论文
共 57 条
  • [1] Abramowitz M., 1970, HDB MATH FUNCTIONS F
  • [2] Polarization effects in flow cytometric DNA sizing
    Agronskaia, A
    Schins, JM
    de Grooth, BG
    Greve, J
    [J]. APPLIED OPTICS, 1999, 38 (04) : 714 - 719
  • [3] Single molecule fluorescence spectroscopy at ambient temperature
    Ambrose, WP
    Goodwin, PM
    Jett, JH
    Van Orden, A
    Werner, JH
    Keller, RA
    [J]. CHEMICAL REVIEWS, 1999, 99 (10) : 2929 - 2956
  • [4] Ambrose WP, 1997, CHEM PHYS LETT, V269, P365, DOI 10.1016/S0009-2614(97)00266-2
  • [5] AMBROSE WP, 2003, TOPICS FLUORESCENCE, V7, P239
  • [6] [Anonymous], 1990, FLOW CYTOM SORTING
  • [7] [Anonymous], [No title captured]
  • [8] Aston C, 1999, METHOD ENZYMOL, V303, P55
  • [9] Optical mapping and its potential for large-scale sequencing projects
    Aston, C
    Mishra, B
    Schwartz, DC
    [J]. TRENDS IN BIOTECHNOLOGY, 1999, 17 (07) : 297 - 302
  • [10] DETECTING SINGLE MOLECULES IN LIQUIDS
    BARNES, MD
    WHITTEN, WB
    RAMSEY, JM
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (13) : A418 - A423