Mottle on computed radiographs of the chest in pediatric patients

被引:35
作者
Huda, W
Slone, RM
Belden, CJ
Williams, JL
Cumming, WA
Palmer, CK
机构
[1] Department of Radiology, University of Florida, College of Medicine, Gainesville, FL 32610-0374
[2] Mallinckrodt Institute of Radiology, Washington University, School of Medicine, St Louis, MO
[3] Department of Radiologic Sciences, Midwestern State University, Wichita Falls, TX
关键词
images; quality; radiography; computer-assisted; in infants and children; thorax;
D O I
10.1148/radiology.199.1.8633153
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the relationship between radiation exposure and perceived mottle at bedside pediatric chest examinations performed with screen-film and computed radiographic techniques. MATERIALS AND METHODS: In a pediatric intensive care unit, chest radiographs were obtained with both computed radiography (60 radiographs) and a 600-speed screen-film system (14 radiographs). The relative radiation exposure was estimated by using the sensitivity value obtained in the processing of each computed radiograph. Five radiologists assessed the mottle present in the computed radiographs and screen-film images. RESULTS: For computed radiographs, the perceived level of mottle was inversely related to radiation exposure. For the same radiation exposure, the perceived mottle on computed radiographs was significantly higher than that on screen-film images (P <.001 for small cassettes; P <.01 for large cassettes). CONCLUSION: Pediatric computed radiography of the chest requires approximately twice the exposure of a 600-speed screen-film system to attain the same level of mottle.
引用
收藏
页码:249 / 252
页数:4
相关论文
共 18 条
[1]  
*AM COLL RAD, PHYS TEACH FIL CAS 1
[2]   DIGITAL RADIOGRAPHY WITH PHOTOSTIMULABLE STORAGE PHOSPHORS - CONTROL OF DETECTOR LATITUDE IN CHEST IMAGING [J].
CHOTAS, HG ;
RAVIN, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (10) :822-828
[3]  
COHEN M D, 1988, Medicamundi, V33, P133
[4]  
COWAN AR, 1993, BRIT J RADIOL, V66, P332
[5]   THRESHOLD PERCEPTION PERFORMANCE WITH COMPUTED AND SCREEN-FILM RADIOGRAPHY - IMPLICATIONS FOR CHEST RADIOGRAPHY [J].
DOBBINS, JT ;
RICE, JJ ;
BEAM, CA ;
RAVIN, CE .
RADIOLOGY, 1992, 183 (01) :179-187
[6]  
FIEBICH M, 1994, SCAR COMP APPL ASS R, P718
[7]  
FREEDMAN M, 1993, P SOC PHOTO-OPT INS, P472
[8]   BASIC IMAGING PROPERTIES OF A COMPUTED RADIOGRAPHIC SYSTEM WITH PHOTOSTIMULABLE PHOSPHORS [J].
FUJITA, H ;
UEDA, K ;
MORISHITA, J ;
FUJIKAWA, T ;
OHTSUKA, A ;
SAI, T .
MEDICAL PHYSICS, 1989, 16 (01) :52-59
[9]  
GUR D, 1993, P 8 EUR C RAD, P154
[10]   IMAGING PERFORMANCE OF A DIGITAL STORAGE PHOSPHOR SYSTEM [J].
HILLEN, W ;
SCHIEBEL, U ;
ZAENGEL, T .
MEDICAL PHYSICS, 1987, 14 (05) :744-751