DIGITAL RADIOGRAPHY WITH PHOTOSTIMULABLE STORAGE PHOSPHORS - CONTROL OF DETECTOR LATITUDE IN CHEST IMAGING

被引:10
作者
CHOTAS, HG
RAVIN, CE
机构
[1] Department of Radiology, Thoracic Imaging Research Division, Duke University Medical Center, Durham, NC
关键词
DIGITAL RADIOGRAPHY; LUNG; PHOTOSTIMULABLE PHOSPHOR; RADIOGRAPHY; STORAGE PHOSPHOR; THORAX;
D O I
10.1097/00004424-199210000-00012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. A widely used digital radiography system based on a photostimulable storage phosphor (PSP) detector was analyzed with regard to radiographic contrast changes that result from the adjustment of detector latitude (x-rav sensitivity range) in the normal processing of chest images. METHODS. Images of an acrylic step wedge were acquired using the digital system in a mode that permitted direct control of effective detector latitude. The images were post-processed in conditions duplicating those used for portable chest examinations, and contrast was measured. RESULTS. Increases in effective detector latitude provided only marginal radiographic contrast gains in the subdiaphragm-equivalent areas of the laser-printed digital film image, while causing large reductions in radiographic contrast in the lung-equivalent region. CONCLUSION. Detector latitude is an important variable that should be monitored or controlled in investigations that compare reader performance using conventional and digital systems.
引用
收藏
页码:822 / 828
页数:7
相关论文
共 13 条
[1]   DETECTION OF PNEUMOTHORAX - COMPARISON OF DIGITAL AND CONVENTIONAL CHEST IMAGING [J].
FAJARDO, LL ;
HILLMAN, BJ ;
POND, GD ;
CARMODY, RF ;
JOHNSON, JE ;
FERRELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :475-480
[2]   2-YEAR CLINICAL-EXPERIENCE WITH A COMPUTED RADIOGRAPHY SYSTEM [J].
KANGARLOO, H ;
BOECHAT, MI ;
BARBARIC, Z ;
TAIRA, RK ;
CHO, PS ;
MANKOVICH, NJ ;
HO, BKT ;
ELDREDGE, SL ;
HUANG, HK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (03) :605-608
[3]   LOW-DOSE DIGITAL COMPUTED RADIOGRAPHY IN PEDIATRIC CHEST IMAGING [J].
KOGUTT, MS ;
JONES, JP ;
PERKINS, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (04) :775-779
[4]   PRELIMINARY EXPERIENCE WITH PORTABLE DIGITAL IMAGING FOR INTENSIVE-CARE RADIOGRAPHY [J].
MARGLIN, SI ;
ROWBERG, AH ;
GODWIN, JD .
JOURNAL OF THORACIC IMAGING, 1990, 5 (01) :49-54
[5]  
Merritt C R, 1985, J Thorac Imaging, V1, P1, DOI 10.1097/00005382-198512000-00003
[6]  
MERRITT CRB, 1985, RADIOGRAPHICS, V5, P397
[7]  
MORIOKA C, 1988, RADIOLOGY, V169, P349
[8]   DIGITAL MOBILE RADIOGRAPHY [J].
SAGEL, SS ;
JOST, RG ;
GLAZER, HS ;
MOLINA, PL ;
ANDERSON, DJ ;
SOLOMON, SL ;
SCHWARBERG, J .
JOURNAL OF THORACIC IMAGING, 1990, 5 (01) :36-48
[9]  
SAITO H, 1988, CLIN RADIOL, V39, P127
[10]   IMPROVED CONTROL OF IMAGE OPTICAL-DENSITY WITH LOW-DOSE DIGITAL AND CONVENTIONAL RADIOGRAPHY IN BEDSIDE IMAGING [J].
SCHAEFER, CM ;
GREENE, RE ;
OESTMANN, JW ;
KAMALSKY, JM ;
HALL, DA ;
LLEWELLYN, HJ ;
ROBERTSON, CL ;
RHEA, JT ;
ROSENTHAL, H ;
RUBENS, JR ;
SHEPARD, JA ;
TEMPLETON, PA .
RADIOLOGY, 1989, 173 (03) :713-716