DIGITAL RADIOGRAPHY;
LUNG;
PHOTOSTIMULABLE PHOSPHOR;
RADIOGRAPHY;
STORAGE PHOSPHOR;
THORAX;
D O I:
10.1097/00004424-199210000-00012
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
RATIONALE AND OBJECTIVES. A widely used digital radiography system based on a photostimulable storage phosphor (PSP) detector was analyzed with regard to radiographic contrast changes that result from the adjustment of detector latitude (x-rav sensitivity range) in the normal processing of chest images. METHODS. Images of an acrylic step wedge were acquired using the digital system in a mode that permitted direct control of effective detector latitude. The images were post-processed in conditions duplicating those used for portable chest examinations, and contrast was measured. RESULTS. Increases in effective detector latitude provided only marginal radiographic contrast gains in the subdiaphragm-equivalent areas of the laser-printed digital film image, while causing large reductions in radiographic contrast in the lung-equivalent region. CONCLUSION. Detector latitude is an important variable that should be monitored or controlled in investigations that compare reader performance using conventional and digital systems.