Computerized analysis of radiographic bone patterns: Effect of imaging conditions on performance

被引:19
作者
Chinander, MR [1 ]
Giger, ML [1 ]
Martell, JM [1 ]
Favus, MJ [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
D O I
10.1118/1.598858
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We are developing computerized methods for characterizing the bone texture pattern from digitized skeletal radiographs. For this method to be useful clinically, it must be able to distinguish between weak and strong bone under the range of exposure conditions potentially encountered in the clinical setting. In this study, we examined the effect of exposure conditions on Fourier-based texture features. Thirty-four femoral specimens from total hip arthroplasties were radiographed multiple times under different exposure conditions. The specimens underwent mechanical strength testing from which load to failure values were obtained. The performance of the texture features were investigated in the task of distinguishing between strong and weak bone as characterized by the load to failure values. The texture features showed no dependence upon focal spot size of the x-ray tube or magnification. The texture features did show a dependence with relative exposure, peak kilovoltage, and amount of scattering material. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:75 / 85
页数:11
相关论文
共 25 条
[1]  
BENHAMOU CL, 1994, J BONE MINER RES, V9, P1909
[2]   COMPUTERIZED RADIOGRAPHIC ANALYSIS OF OSTEOPOROSIS - PRELIMINARY EVALUATION [J].
CALIGIURI, P ;
GIGER, ML ;
FAVUS, MJ ;
JIA, H ;
DOI, K ;
DIXON, LB .
RADIOLOGY, 1993, 186 (02) :471-474
[3]   MULTIFRACTAL RADIOGRAPHIC ANALYSIS OF OSTEOPOROSIS [J].
CALIGIURI, P ;
GIGER, ML ;
FAVUS, M .
MEDICAL PHYSICS, 1994, 21 (04) :503-508
[4]   QUANTITATIVE COMPUTED-TOMOGRAPHY FOR PREDICTION OF VERTEBRAL FRACTURE RISK [J].
CANN, CE ;
GENANT, HK ;
KOLB, FO ;
ETTINGER, B .
BONE, 1985, 6 (01) :1-7
[5]   FRACTAL ANALYSIS OF TRABECULAR PATTERNS IN PROJECTION RADIOGRAPHS - AN ASSESSMENT [J].
CHEN, J ;
ZHENG, B ;
CHANG, YH ;
SHAW, CC ;
TOWERS, JD ;
GUR, D .
INVESTIGATIVE RADIOLOGY, 1994, 29 (06) :624-629
[6]   Computerized radiographic texture measures for characterizing bone strength: A simulated clinical setup using femoral neck specimens [J].
Chinander, MR ;
Giger, ML ;
Martell, JM ;
Jiang, C ;
Favus, MJ .
MEDICAL PHYSICS, 1999, 26 (11) :2295-2300
[7]   RADIOGRAPHIC APPLICATIONS OF RECEIVER OPERATING CHARACTERISTIC (ROC) CURVES [J].
GOODENOUGH, DJ ;
ROSSMANN, K ;
LUSTED, LB .
RADIOLOGY, 1974, 110 (01) :89-95
[8]  
Hurley DL, 1997, MAYO CLIN PROC, V72, P943
[9]   Characterization of bone quality using computer-extracted radiographic features [J].
Jiang, CS ;
Giger, ML ;
Chinander, MR ;
Martell, JM ;
Kwak, S ;
Favus, MJ .
MEDICAL PHYSICS, 1999, 26 (06) :872-879
[10]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY - DETECTION AND CHARACTERIZATION OF INTERSTITIAL LUNG-DISEASE IN DIGITAL CHEST RADIOGRAPHS [J].
KATSURAGAWA, S ;
DOI, K ;
MACMAHON, H .
MEDICAL PHYSICS, 1988, 15 (03) :311-319