Atmospheric pressure matrix assisted laser desorption/ionization mass spectrometry

被引:333
作者
Laiko, VV
Baldwin, MA
Burlingame, AL [1 ]
机构
[1] Univ Calif San Francisco, Mass Spectrometry Facil, Dept Pharmaceut Chem, Dept Neurol, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Inst Neurol Dis, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Ctr Liver, San Francisco, CA 94143 USA
关键词
D O I
10.1021/ac990998k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
sA novel ionization source for biological mass spectrometry is described that combines atmospheric pressure (AP) ionization and matrix-assisted laser desorption/ionization (MALDI), The transfer of the ions from the atmospheric pressure ionization region to the high vacuum is pneumatically assisted (PA) by a stream of nitrogen, hence the acronym PA-AP MALDI, PA-AP MALDI is readily interchangeable with electrospray ionization on an orthogonal acceleration time-of-flight (oaTOF) mass spectrometer, Sample preparation is identical to that for conventional vacuum MALDI and uses the same matrix compounds, such as alpha-cyano-4-hydroxycinnamic acid. The performance of this ion source on the oaTOF mass spectrometer is compared with that of conventional vacuum MALDI-TOF for the analysis of peptides, PA-AP MALDI can detect low femtomole amounts of peptides in mixtures with good signal-to-noise ratio and with less discrimination for the detection of individual peptides in a protein digest. Peptide ions produced by this method generally exhibit no metastable fragmentation, whereas an oligosaccharide ionized by PA-AP MALDI shows several structurally diagnostic fragment ions. Total sample consumption is higher for PA-AP MALDI than for vacuum MALDI, as the transfer of ions into the vacuum system is relatively inefficient. This ionization method is able to produce protonated molecular ions for small proteins such as insulin, but these tend to form clusters with the matrix material. Limitations of the oaTOF mass spectrometer for singly charged high-mass ions make it difficult to evaluate the ionization of larger proteins.
引用
收藏
页码:652 / 657
页数:6
相关论文
共 16 条
[1]  
BROWN RS, 1995, J ANAL CHEM+, V67, P1998
[2]   IMPROVING THE RESOLUTION OF MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY BY EXPLOITING THE CORRELATION BETWEEN ION POSITION AND VELOCITY [J].
COLBY, SM ;
KING, TB ;
REILLY, JP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (11) :865-868
[3]  
DODONOV AF, 1994, ACS SYM SER, V549, pCH7
[4]   A SYSTEMATIC NOMENCLATURE FOR CARBOHYDRATE FRAGMENTATIONS IN FAB-MS MS SPECTRA OF GLYCOCONJUGATES [J].
DOMON, B ;
COSTELLO, CE .
GLYCOCONJUGATE JOURNAL, 1988, 5 (04) :397-409
[5]  
DZIEGIELEWSKA KM, 1990, J BIOL CHEM, V265, P4354
[6]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[7]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[8]  
LAIKO VV, 1999, Patent No. 5965884
[9]   CHARACTERIZATION OF PROTEIN N-GLYCOSYLATION BY REVERSED-PHASE MICROBORE LIQUID-CHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY, COMPLEMENTARY MOBILE PHASES, AND SEQUENTIAL EXOGLYCOSIDASE DIGESTION [J].
MEDZIHRADSZKY, KF ;
MALTBY, DA ;
HALL, SC ;
SETTINERI, CA ;
BURLINGAME, AL .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (05) :350-358
[10]   ULTRAVIOLET-LASER DESORPTION IONIZATION MASS-SPECTROMETRY OF PROTEINS ABOVE 100000 DALTONS BY PULSED ION EXTRACTION TIME-OF-FLIGHT ANALYSIS [J].
SPENGLER, B ;
COTTER, RJ .
ANALYTICAL CHEMISTRY, 1990, 62 (08) :793-796