Tuning of an electrospray ionization source for maximum peptide-ion transmission into a mass spectrometer

被引:69
作者
Geromanos, S
Freckleton, G
Tempst, P
机构
[1] Mem Sloan Kettering Canc Ctr, Prot Ctr, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Program Mol Biol, New York, NY 10021 USA
关键词
D O I
10.1021/ac991071n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe assembly and optimization of a continuous now nanoelectrospray source for high-performance analysis on a routine basis. It is derived from an inJection adaptable Fine Ionization Source ("JaFIS"), previously shown to be durable and easy to use (Geromanos, S.; et al, Rapid Commun, Mass Spectrom, 1998, 12, 551-556) and now modified for maximum sensitivity. Proper design, manufacturing, and quality control of spray needles with specific orifice diameters, in combination with precisely controlled helium backpressure and applied voltage, enable stable flows at 1-2 nL/min, Needle positioning and ion spray potential are hereby exceedingly important, as shifts by 0.5 mm or 25 V, respectively, cause significant reduction in signal strength. In addition to prolonged analysis times, ultralow flows also yield higher sensitivity, the result of an improved "overall ion transfer efficiency" measured to be similar to 5% at 1.6 nL/min. Used in combination with a "microtip" (Erdjument-Bromage, H.; et al. J. Chromatogr. A 1998, 826, 167-181), the optimized JaFIS implements infusion-style ESI-MS at sensitivities approaching capillary LC-MS, Spraying times in excess of 20 h allow for any number of tandem mass spectrometric analysis routines to be performed, and to average thousands of scans in every experiment, thereby further improving sensitivity. This was fully illustrated by extensive analysis of a 2-fmol peptide mixture, in a 2-mu L volume, using a multimode MS approach.
引用
收藏
页码:777 / 790
页数:14
相关论文
共 75 条
  • [51] Immobilized gallium(III) affinity chromatography of phosphopeptides
    Posewitz, MC
    Tempst, P
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (14) : 2883 - 2892
  • [52] Generating electrospray from microchip devices using electroosmotic pumping
    Ramsey, RS
    Ramsey, JM
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (06) : 1174 - 1178
  • [53] Mass spectrometry in protein studies from genome to function
    Roepstorff, P
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1997, 8 (01) : 6 - 13
  • [54] ELECTROSPRAY MASS-SPECTROMETRY - APPLICATION OF ION EVAPORATION THEORY TO AMINO-ACIDS
    SAKAIRI, M
    YERGEY, AL
    SIU, KWM
    LEBLANC, JCY
    GUEVREMONT, R
    BERMAN, SS
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (14) : 1488 - 1490
  • [55] DESOLVATION OF IONS AND MOLECULES IN THERMOSPRAY MASS-SPECTROMETRY
    SCHMELZEISENREDEKER, G
    BUTFERING, L
    ROLLGEN, FW
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 90 (02): : 139 - 150
  • [56] Linking genome and proteome by mass spectrometry: Large-scale identification of yeast proteins from two dimensional gels
    Shevchenko, A
    Jensen, ON
    Podtelejnikov, AV
    Sagliocco, F
    Wilm, M
    Vorm, O
    Mortensen, P
    Shevchenko, A
    Boucherie, H
    Mann, M
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (25) : 14440 - 14445
  • [57] NEW DEVELOPMENTS IN BIOCHEMICAL MASS-SPECTROMETRY - ELECTROSPRAY IONIZATION
    SMITH, RD
    LOO, JA
    EDMONDS, CG
    BARINAGA, CJ
    UDSETH, HR
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (09) : 882 - 899
  • [58] Net1, a Sir2-associated nucleolar protein required for rDNA silencing and nucleolar integrity
    Straight, AF
    Shou, WY
    Dowd, GJ
    Turck, CW
    Deshaies, RJ
    Johnson, AD
    Moazed, D
    [J]. CELL, 1999, 97 (02) : 245 - 256
  • [59] DEPENDENCE OF ION INTENSITY IN ELECTROSPRAY MASS-SPECTROMETRY ON THE CONCENTRATION OF THE ANALYTES IN THE ELECTROSPRAYED SOLUTION
    TANG, L
    KEBARLE, P
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (24) : 3654 - 3668
  • [60] FIELD-INDUCED ION EVAPORATION FROM LIQUID SURFACES AT ATMOSPHERIC-PRESSURE
    THOMSON, BA
    IRIBARNE, JV
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1979, 71 (11) : 4451 - 4463