Selection of the optimum b factor for diffusion-weighted magnetic resonance imaging assessment of ischemic stroke

被引:46
作者
Kingsley, PB [1 ]
Monahan, WG [1 ]
机构
[1] NYU, Sch Med, Dept Radiol, New York, NY USA
关键词
anisotropy; diffusion; infarct; optimization;
D O I
10.1002/mrm.20059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine the diffusion sensitivity factor b that optimizes the contrast-to-noise ratio (CNR) for both diffusion-weighted signal intensity and the apparent diffusion coefficient (ADCNR) when evaluating ischemic stroke by diffusion-weighted MRI. The relative contrast, noise levels, CNR, and ADCNR were calculated for typical ADC values in human brain, 780 mum(2)/s in adults and 1200 mum(2)/s in neonates in normal tissue, 20-40% less in acute and subacute stroke, and 50% more in chronic stroke. The optimum b factor depends strongly on the ADC, whether TE is fixed or varies with the b factor, whether CNR or ADCNR is measured, and anisotropy. The optimum b factor in adults is 1000 s/mm(2) in acute and chronic stroke, and 1200 s/mm(2) in subacute stroke. The optimum values are about 200 s/mm(2) lower in neonates than in adults. The CNR and ADCNR are within 10% of the optimum over at least a 2-fold range of b factors, from 68-136% of the optimum b factor. If a single b factor is to be used for all situations, a diffusion b factor of 1000 s/mm(2) is recommended. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:996 / 1001
页数:6
相关论文
共 37 条
[1]   Utilizing the diffusion-to-noise ratio to optimize magnetic resonance diffusion tensor acquisition strategies for improving measurements of diffusion anisotropy [J].
Armitage, PA ;
Bastin, ME .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :1056-1065
[2]  
Beaulieu C, 1999, ANN NEUROL, V46, P568, DOI 10.1002/1531-8249(199910)46:4<568::AID-ANA4>3.0.CO
[3]  
2-R
[4]   IMPROVED DETECTABILITY IN LOW SIGNAL-TO-NOISE RATIO MAGNETIC-RESONANCE IMAGES BY MEANS OF A PHASE-CORRECTED REAL RECONSTRUCTION [J].
BERNSTEIN, MA ;
THOMASSON, DM ;
PERMAN, WH .
MEDICAL PHYSICS, 1989, 16 (05) :813-817
[5]   Acute cerebral infarction: Quantification of spin-density and T2 shine-through phenomena on diffusion-weighted MR images [J].
Burdette, JH ;
Elster, AD ;
Ricci, PE .
RADIOLOGY, 1999, 212 (02) :333-339
[6]  
Clark CA, 2000, MAGN RESON MED, V44, P852, DOI 10.1002/1522-2594(200012)44:6<852::AID-MRM5>3.0.CO
[7]  
2-A
[8]   Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results [J].
Conturo, TE ;
McKinstry, RC ;
Akbudak, E ;
Robinson, BH .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :399-412
[9]   CONSIDERATION OF RANDOM ERRORS IN THE QUANTITATIVE IMAGING OF NMR RELAXATION [J].
DORAN, SJ ;
ATTARD, JJ ;
ROBERTS, TPL ;
CARPENTER, TA ;
HALL, LD .
JOURNAL OF MAGNETIC RESONANCE, 1992, 100 (01) :101-122
[10]   A SIGNAL-TO-NOISE CALIBRATION PROCEDURE FOR NMR IMAGING-SYSTEMS [J].
EDELSTEIN, WA ;
BOTTOMLEY, PA ;
PFEIFER, LM .
MEDICAL PHYSICS, 1984, 11 (02) :180-185