Impaction bone grafting of the acetabulum at hip revision using a mix of bone chips and a biphasic porous ceramic bone graft substitute

被引:49
作者
Blom, Ashley W. [1 ,2 ]
Wylde, Vikki [1 ]
Livesey, Christine [1 ]
Whitehouse, Michael R. [1 ,2 ]
Eastaugh-Waring, Steve [2 ]
Bannister, Gordon C. [2 ]
Learmonth, Ian D. [1 ]
机构
[1] Univ Bristol, Dept Acad Orthopaed, BIRC Res Labs, Avon Orthopaed Ctr, Bristol BS10 5NB, Avon, England
[2] Southmead Hosp, Avon Orthopaed Ctr, N Bristol NHS Trust, Dept Orthopaed, Bristol BS10 5NB, Avon, England
关键词
TRICALCIUM-PHOSPHATE; CUP STABILITY; CEMENTED CUP; PORE-SIZE; HYDROXYAPATITE; SURGERY; ARTHROPLASTY; ALLOGRAFT; CLASSIFICATION; RECONSTRUCTION;
D O I
10.3109/17453670902884767
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background and purpose One of the greatest problems of revision hip arthroplasty is dealing with lost bone stock. Good results have been obtained with impaction grafting of allograft bone. However, there have been problems of infection, reproducibility, antigenicity, stability, availability of bone, and cost. Thus, alternatives to allograft have been sought. BoneSave is a biphasic porous ceramic specifically designed for use in impaction grafting. BoneSave is 80% tricalcium phosphate and 20% hydroxyapatite. Previous in vitro and in vivo studies have yielded good results using mixtures of allograft and BoneSave, when compared with allograft alone. This study is the first reported human clinical trial of BoneSave in impaction grafting. Methods We performed a single-institution, multi-surgeon, prospective cohort study. 43 consecutive patients underwent revision hip arthroplasty using BoneSave and allograft to restore missing bone in the acetabulum. 9 patients had cemented acetabular components implanted and 34 uncemented. 10 patients had cemented femoral components implanted and 1 had an uncemented femoral component. 32 patients did not have their femoral component revised. Results No patients were lost to follow-up. At a mean follow-up of 24 (11-48) months, there were no re-revisions and there was no implant migration. 1 acetabular component had confluent lucent lines at the implant-graft interface. Complications were rare (1 fracture, 2 dislocations). Patient satisfaction with the procedure was high. Interpretation Short-term results indicate that impaction grafting of BoneSave and allograft is an effective method of dealing with loss of bone stock at revision hip surgery.
引用
收藏
页码:150 / 154
页数:5
相关论文
共 36 条
[1]
Cemented cup stability during lever-out testing after acetabular bone impaction grafting with bone graft substitutes mixes containing morselized cancellous bone and tricalcium phosphate-hydroxyapatite granules [J].
Arts, JJC ;
Schreurs, BW ;
Buma, P ;
Verdonschot, N .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H4) :257-263
[2]
No negative effects of bone impaction grafting with bone and ceramic mixtures [J].
Arts, JJC ;
Gardeniers, JWM ;
Welten, MLM ;
Verdonschot, N ;
Schreurs, BW ;
Buma, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) :239-247
[3]
COMPARATIVE-STUDY OF THE OSTEOINDUCTIVE PROPERTIES OF BIOCERAMIC, CORAL AND PROCESSED BONE-GRAFT SUBSTITUTES [J].
BEGLEY, CT ;
DOHERTY, MJ ;
MOLLAN, RAB ;
WILSON, DJ .
BIOMATERIALS, 1995, 16 (15) :1181-1185
[4]
Revision of an acetabular liner has a high risk of dislocation [J].
Blom, AW ;
Astle, L ;
Loveridge, J ;
Learmonth, ID .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (12) :1636-1638
[5]
Blom AW, 2005, J BONE JOINT SURG BR, V87B, P421, DOI 10.1302/0301-620X.87B3
[6]
Infection after total hip arthroplasty - The avon experience [J].
Blom, AW ;
Taylor, AH ;
Pattison, G ;
Whitehouse, S ;
Bannister, GC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (07) :956-959
[7]
Subsidence in impaction grafting: the effect of adding a ceramic bone graft extender to bone [J].
Blom, AW ;
Grimm, B ;
Miles, AW ;
Cunningham, JL ;
Learmonth, ID .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H4) :265-270
[8]
Technical factors affecting cup stability in bone impaction grafting [J].
Bolder, S. B. T. ;
Verdonschot, N. ;
Schreurs, B. W. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H1) :81-86
[9]
CEMENTED C, 2004, J BONE JOINT SURG AM, V2385, P92
[10]
Poor results after augmenting autograft with xenograft (Surgibone) in hip revision surgery - A report of 27 cases [J].
Charalambides, C ;
Beer, M ;
Cobb, AG .
ACTA ORTHOPAEDICA, 2005, 76 (04) :544-549