Technical factors affecting cup stability in bone impaction grafting

被引:16
作者
Bolder, S. B. T. [1 ]
Verdonschot, N. [1 ]
Schreurs, B. W. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Orthopaed, NL-6500 HB Nijmegen, Netherlands
关键词
hip; arthroplasty; cement; bone graft; revision;
D O I
10.1243/09544119JEIM245
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Favourable long-term clinical results can be achieved by the bone impaction technique in bone stock deficient acetabuli. Originally, firm impaction of manually prepared bone grafts using a rongeur was performed. An alternative technique for producing bone grafts is reaming from the pelvic wall or femoral head, which produces smaller-sized slurry bone grafts. These slurry grafts can be manually compressed in the bone defect using an acetabular reamer en reverse. In an artificial acetabular cavitary defect model both reconstruction techniques were compared in combination with a cemented cup. Mechanical testing was performed with a sequentially increasing dynamic load. Roentgen stereophotogrammetric analysis was used to determine initial cup stability At all testing levels the initial stability of the cups reconstructed with slurry grafts and reversed reaming was significantly less in comparison to the original impaction technique. The original technique with firm impaction with a hammer and impactors of relatively large-sized bone grafts provides optimal initial stability. The reversed reaming technique of slurry grafts cannot be recommended for bone grafting of acetabular defects.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 26 条
[1]
Larger bone graft size and washing of bone grafts prior to impaction enhances the initial stability of cemented cups - Experiments using a synthetic acetabular model [J].
Arts, J. J. Chris ;
Verdonschot, Nico ;
Buma, Pieter ;
Schreurs, B. Willem .
ACTA ORTHOPAEDICA, 2006, 77 (02) :227-233
[2]
Cemented cup stability during lever-out testing after acetabular bone impaction grafting with bone graft substitutes mixes containing morselized cancellous bone and tricalcium phosphate-hydroxyapatite granules [J].
Arts, JJC ;
Schreurs, BW ;
Buma, P ;
Verdonschot, N .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H4) :257-263
[3]
Acetabular defect reconstruction with impacted morsellized bone grafts or TCP/HA particles. A study on the mechanical stability of cemented cups in an artificial acetabulum model [J].
Bolder, SBT ;
Verdonschot, N ;
Schreurs, BW ;
Buma, P .
BIOMATERIALS, 2002, 23 (03) :659-666
[4]
The initial stability of cemented acetabular cups can be augmented by mixing morsellized bone grafts with tricalciumphosphate/hydroxyapatite particles in bone impaction grafting [J].
Bolder, SBT ;
Verdonschot, N ;
Schreurs, BW ;
Buma, P .
JOURNAL OF ARTHROPLASTY, 2003, 18 (08) :1056-1063
[5]
Particle size of bone graft and method of impaction affect initial stability of cemented cups - Human cadaveric and synthetic pelvic specimen studies [J].
Bolder, SBT ;
Schreurs, BW ;
Verdonschot, N ;
van Unen, JMJ ;
Gardeniers, JWM ;
Slooff, TJJH .
ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (06) :652-657
[6]
Cemented total hip arthroplasty with impacted morcellized bone-grafts to restore acetabular bone defects in congenital hip dysplasia [J].
Bolder, SBT ;
Melenhorst, J ;
Gardeniers, JWM ;
Slooff, TJJH ;
Veth, RPH ;
Schreurs, BW .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :164-169
[8]
Techniques to improve the shear strength of impacted bone graft - The effect of particle size and washing of the graft [J].
Dunlop, DG ;
Brewster, NT ;
Madabhushi, SPG ;
Usmani, AS ;
Pankaj, P ;
Howie, CR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (04) :639-646
[9]
ELDRIDGE JDJ, 1997, J BONE JOINT SURG BR, V79, P364
[10]
The incorporation of morselized bone grafts in cementless acetabular revisions [J].
Etienne, G ;
Bezwada, HP ;
Hungerford, DS ;
Mont, MA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :241-246