auto-tuning;
PID control;
process control;
relay control;
disturbance rejection;
D O I:
10.1016/S0005-1098(96)00174-4
中图分类号:
TP [自动化技术、计算机技术];
学科分类号:
0812 ;
摘要:
In the presence of static load disturbance, a relay auto-tuning experiment shows significant errors in estimating the ultimate gain and period. This paper shows how to overcome the problem without any information on the static gain of the process and how to obtain process gain from one relay experiment. (C) 1997 Elsevier Science Ltd.