A flow injection kinase assay system based on time-resolved fluorescence resonance energy-transfer detection in the millisecond range

被引:9
作者
Hirata, J [1 ]
de Jong, CF [1 ]
van Dongen, MM [1 ]
Buijs, J [1 ]
Ariese, F [1 ]
Irth, H [1 ]
Gooijer, C [1 ]
机构
[1] Vrije Univ Amsterdam, Ctr Laser, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
关键词
D O I
10.1021/ac049465o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis (FIA) system for biochemical assays using time-resolved fluorescence resonance energy transfer (TR-FRET) in the millisecond time scale was developed. As a model system, we studied a kinase assay, measuring the phosphorylation of poly(GT)-biotin (substrate) by a receptor tyrosine kinase (epidermal growth factor receptor). A streptavidin labeled with XL665 (SA-XL665)-the acceptor-was coupled to the biotin moiety, and an antiphosphotyrosine antibody labeled with europium cryptate (Ab-EuK)-the donor-was coupled to the phosphorylated tyrosine group(s). Long-lived FRET can only occur if the substrate is successfully phosphorylated. For the time-resolved detection of such long-lived luminescence phenomena in a flow system, the repetition rate of the excitation source plays a crucial role. Good results were obtained for a small-sized commercially available quadrupled Nd:YAG laser emitting at 266 nm with a repetition rate of 7.8 kHz and a pulse width of 0.3 ns. The long-lived emissions of the donor at 625 nm and that of the acceptor at 665 nm were monitored simultaneously with two photomultipliers, using a delay time of 50 jus and a gate time of 75 us to exclude background fluorescence interferences. In the FIA experiments, the Ab-EuK concentration was 6 nM and the substrate concentration and SA-XL665 concentrations were 7 nM. By monitoring the intensity changes at 625 and 665 nm, the inhibition of tyrosine kinase by tyrphostin AG1478 was studied and an IC50 value of 5.1 +/- 0.4 nM obtained.
引用
收藏
页码:4292 / 4298
页数:7
相关论文
共 28 条
[1]   Time-resolved fluorometric assay for detection of autoantibodies to glutamic acid decarboxylase (GAD65) [J].
Ankelo, M ;
Westerlund-Karlsson, A ;
Ilonen, J ;
Knip, M ;
Savola, K ;
Kankaapää, P ;
Meriö, L ;
Siitari, H ;
Hinkkanen, A .
CLINICAL CHEMISTRY, 2003, 49 (06) :908-915
[2]  
Bazin H, 2002, J Biotechnol, V82, P233, DOI 10.1016/S1389-0352(01)00040-X
[3]   Optical Imaging fiber-based single live cell arrays: A high-density cell assay platform [J].
Biran, I ;
Walt, DR .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :3046-3054
[4]   On-line continuous-flow, multi-protein biochemical assays for the characterization of bioaffinity compounds using electrospray quadrupole time-of-flight mass spectrometry [J].
Derks, RJE ;
Hogenboom, AC ;
van der Zwan, G ;
Irth, H .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3376-3384
[5]   High-performance liquid chromatographic analysis of the tyrphostin AG1478, a specific inhibitor of the epidermal growth factor receptor tyrosine kinase, in mouse plasma [J].
Ellis, AG ;
Nice, EC ;
Weinstock, J ;
Levitzki, A ;
Burgess, AW ;
Webster, LK .
JOURNAL OF CHROMATOGRAPHY B, 2001, 754 (01) :193-199
[6]   Proton-activated fluorescence as a tool for simultaneous screening of combinatorial chemical reactions [J].
Evans, CA ;
Miller, SJ .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2002, 6 (03) :333-338
[7]   Protein kinases as targets for anticancer agents: from inhibitors to useful drugs [J].
Fabbro, D ;
Ruetz, S ;
Buchdunger, E ;
Cowan-Jacob, SW ;
Fendrich, G ;
Liebetanz, J ;
Mestan, J ;
O'Reilly, T ;
Traxler, P ;
Chaudhuri, B ;
Fretz, H ;
Zimmermann, J ;
Meyer, T ;
Caravatti, G ;
Furet, P ;
Manley, PW .
PHARMACOLOGY & THERAPEUTICS, 2002, 93 (2-3) :79-98
[8]   An evaluation of fluorescence polarization and lifetime discriminated polarization for high throughput screening of serine/threonine kinases [J].
Fowler, A ;
Swift, D ;
Longman, E ;
Acornley, A ;
Hemsley, P ;
Murray, D ;
Unitt, J ;
Dale, I ;
Sullivan, E ;
Coldwell, M .
ANALYTICAL BIOCHEMISTRY, 2002, 308 (02) :223-231
[9]  
GREEN NM, 1990, METHOD ENZYMOL, V184, P51
[10]   Epidermal growth factor receptors: critical mediators of multiple receptor pathways [J].
Hackel, PO ;
Zwick, E ;
Prenzel, N ;
Ullrich, A .
CURRENT OPINION IN CELL BIOLOGY, 1999, 11 (02) :184-189