On-line continuous-flow, multi-protein biochemical assays for the characterization of bioaffinity compounds using electrospray quadrupole time-of-flight mass spectrometry

被引:14
作者
Derks, RJE [1 ]
Hogenboom, AC [1 ]
van der Zwan, G [1 ]
Irth, H [1 ]
机构
[1] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, Div Chem, Fac Sci, NL-1081 HV Amsterdam, Netherlands
关键词
D O I
10.1021/ac026423w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The applicability of a homogeneous on-line continuous-flow, multi-protein biochemical assay was demonstrated for the interaction between fluorescein-biotin and streptavidin and for digoxin and anti-digoidgenin using electrospray quadrupole time-of-flight mass spectrometry (Q-TOF MS). In the on-line continuous-flow biochemical MS-based system several receptors (e.g., streptavidin and anti-digoxigenin, respectively) were allowed to react with corresponding reporter ligands (e.g.,fluorescein-biotin and digoxin, respectively). The methodology presented allows the simultaneous measurement of affinity and molecular mass of an active compound. By using automated MS and MS-MS switching functions of the Q-TOF, structure information is obtained allowing the characterization of bioactive compounds. No cross-reactivities were observed between the two model systems fluorescein-biotin/streptavidin and digoxin/anti-digoxigenin.
引用
收藏
页码:3376 / 3384
页数:9
相关论文
共 17 条
[1]   BIOSPECIFIC DETECTION IN LIQUID-CHROMATOGRAPHY [J].
EMNEUS, J ;
MARKOVARGA, G .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :191-243
[2]   OBSERVATION OF NONCOVALENT ENZYME SUBSTRATE AND ENZYME PRODUCT COMPLEXES BY ION-SPRAY MASS-SPECTROMETRY [J].
GANEM, B ;
LI, YT ;
HENION, JD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (20) :7818-7819
[3]   DETECTION OF NONCOVALENT RECEPTOR LIGAND COMPLEXES BY MASS-SPECTROMETRY [J].
GANEM, B ;
LI, YT ;
HENION, JD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (16) :6294-6296
[4]   High-performance liquid chromatography with on-line post-column immunoreaction detection of digoxin and its metabolites based on fluorescence energy transfer in the far-red spectral region [J].
Graefe, KA ;
Tang, Z ;
Karnes, HT .
JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (02) :305-314
[5]   Affinity capillary electrophoresis: important application areas and some recent developments [J].
Heegaard, NHH ;
Nilsson, S ;
Guzman, NA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 715 (01) :29-54
[6]   Use of a partial-filling technique in affinity capillary electrophoresis for determining binding constants of ligands to receptors [J].
Heintz, J ;
Hernandez, M ;
Gomez, FA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 840 (02) :261-268
[7]   Continuous-flow, on-line monitoring of biospecific interactions using electrospray mass spectrometry [J].
Hogenboom, AC ;
de Boer, AR ;
Derks, RJE ;
Irth, H .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :3816-3823
[8]   STRATEGIES FOR ONLINE COUPLING OF IMMUNOASSAYS TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IRTH, H ;
OOSTERKAMP, AJ ;
TJADEN, UR ;
VANDERGREEF, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) :355-361
[9]  
Loo JA, 1997, MASS SPECTROM REV, V16, P1
[10]   High sample throughput flow immunoassay utilising restricted access columns for the separation of bound and free label [J].
Önnerfjord, P ;
Eremin, SA ;
Emnéus, J ;
Marko-Varga, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 800 (02) :219-230