High-performance liquid chromatography with on-line post-column immunoreaction detection of digoxin and its metabolites based on fluorescence energy transfer in the far-red spectral region

被引:16
作者
Graefe, KA [1 ]
Tang, Z [1 ]
Karnes, HT [1 ]
机构
[1] Virginia Commonwealth Univ, Med Coll Virginia, Dept Pharmaceut, Richmond, VA 23298 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 745卷 / 02期
关键词
hapten conjugation; fluorescence energy transfer; digoxin; phycoerythrin; Cy5;
D O I
10.1016/S0378-4347(00)00304-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The combination of immunoassays with separation techniques such as chromatography can result in enhanced selectivity and sensitivity. This paper describes an on-line chromatography with immunochemical post-column fluorescence energy transfer detection for digoxin and its metabolites. R-phycoerythrin (PE) was used as the donor and an indodicarbocyanine dye (Cy5) as the acceptor label. These labels allow the detection in the far-red spectral region, which is more selective for biological samples. Hence, digoxin was labeled with PE using the activated digoxigenin-NHS-ester and monoclonal anti-digoxin antibody was labeled with Cy5. Digoxin and its metabolites was injected into the HPLC system followed by post-column injection of R-phycoerythrin labeled digoxin and by Cy5 labeled anti-digoxin antibody. Incubation time was provided using an open tubular reactor coil at room temperature. The detection was performed by measurement of the sensitized emission of Cy5 at 670 mm due to fluorescence energy transfer from PE labeled with digoxin. The system was optimized with regard to the concentrations of the used post-column reagents as well as incubation time and temperature. The dynamic range of digoxin spiked in 0.01 M phosphate buffer (pH 7.4) was 0.05 to 10 ng/ml with a correlation coefficient of 0.989. The limit of detection was 33 pg/ml. The precision of two controls, 0.4 and 4 ng/ml, was found to be 2.2 and 8.7% RSD, respectively, accuracy was 10.7 and 20.3% (n=6 in each case). (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 19 条
[1]  
*AM LIF SCI, 1999, FLUOR CY5 LAB KIT PR
[2]   CLINICAL PHARMACOKINETICS OF DIGOXIN 1980 [J].
ARONSON, JK .
CLINICAL PHARMACOKINETICS, 1980, 5 (02) :137-149
[3]   CHARACTERIZATION OF DIGOXIGENIN-LABELED B-PHYCOERYTHRIN BY CAPILLARY ELECTROPHORESIS WITH LASER-INDUCED FLUORESCENCE - APPLICATION TO HOMOGENEOUS DIGOXIN IMMUNOASSAY [J].
CHEN, FTA ;
PENTONEY, SL .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (02) :425-430
[4]   TANDEM CHROMATOGRAPHIC-IMMUNOLOGICAL ANALYSES [J].
DEFRUTOS, M ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1993, 65 (01) :A17-&
[5]   CHROMATOGRAPHY IMMUNOLOGY COUPLING, A POWERFUL TOOL FOR ENVIRONMENTAL-ANALYSIS [J].
DEFRUTOS, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (03) :133-140
[6]  
EMBREE L, 1989, J CHROMATOGR-BIOMED, V496, P321
[7]  
FREYTAG JW, 1984, CLIN CHEM, V30, P1494
[8]   PHYCOFLUOR PROBES [J].
GLAZER, AN ;
STRYER, L .
TRENDS IN BIOCHEMICAL SCIENCES, 1984, 9 (10) :423-427
[9]   ONLINE IMMUNOCHEMICAL DETECTION IN LIQUID-CHROMATOGRAPHY USING FLUORESCEIN-LABELED ANTIBODIES [J].
IRTH, H ;
OOSTERKAMP, AJ ;
VANDERWELLE, W ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2) :65-72
[10]   STRATEGIES FOR ONLINE COUPLING OF IMMUNOASSAYS TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IRTH, H ;
OOSTERKAMP, AJ ;
TJADEN, UR ;
VANDERGREEF, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) :355-361