Quantitative assessment of stenotic aortic valve area by using intracardiac echocardiography: In vitro validation and initial in vivo illustration

被引:11
作者
Jiang, L
DePrada, JAV
Lee, MY
Ba, JH
Padial, LR
Fallon, JT
King, ME
Palacios, IF
Weyman, AE
Levine, RA
机构
[1] Cardiac Ultrasound VBK 508, Massachusetts General Hospital, Boston
关键词
D O I
10.1016/S0002-8703(96)90402-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Quantitative assessment of aortic stenosis (AS) is subject to the limitations of all current noninvasive and invasive methods. The ability to obtain a direct measure of aortic valve area with high resolution by intracardiac echocardiography (ICE) could be of great benefit to catheterized patients. To provide a fixed AS area as an ideal standard for comparison, we performed ICE in 12 sheep hearts with experimentally created AS and five human AS hearts from autopsies. ICE catheters were passed retrograde across the aortic valve, and the minimal orifice area on pullback was planimetered and compared with calibrated video imaging. The entire orifice circumference could be successfully recorded in 16 (94%) hearts. Orifice area from ICE correlated well with actual values (r = 0.98; standard error of the estimate [SEE] = 0.06 cm(2)). To illustrate the applicability in vivo, two canine models and 10 patients with AS were studied. The limiting orifice could be imaged in both animals and in 8 of 10 patients, in whom values agreed well with invasive data (r = 0.95; SEE = 0.04 cm(2)). ICE can therefore accurately measure AS orifice area in vitro; it can be applied in vivo as well. These validation studies laid the foundation for subsequent clinical studies and applications.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 35 条
[11]   VALUE AND LIMITATIONS OF CROSS-SECTIONAL ECHOCARDIOGRAPHY OF THE AORTIC-VALVE IN THE DIAGNOSIS AND QUANTIFICATION OF VALVULAR AORTIC-STENOSIS [J].
DEMARIA, AN ;
BOMMER, W ;
JOYE, J ;
LEE, G ;
BOUTELLER, J ;
MASON, DT .
CIRCULATION, 1980, 62 (02) :304-312
[12]   INTRACARDIAC ULTRASOUND DETERMINATION OF LEFT-VENTRICULAR VOLUMES - IN-VITRO AND IN-VIVO VALIDATION [J].
FISHER, JP ;
WOLFBERG, CA ;
MIKAN, JS ;
KIERNAN, FJ ;
FRAM, DB ;
MCKAY, RG ;
GILLAM, LD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (01) :247-253
[13]   INFLUENCE OF ORIFICE GEOMETRY AND FLOW-RATE ON EFFECTIVE VALVE AREA - AN INVITRO STUDY [J].
FLACHSKAMPF, FA ;
WEYMAN, AE ;
GUERRERO, JL ;
THOMAS, JD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (05) :1173-1180
[14]   LOW-FREQUENCY INTRACARDIAC ULTRASONOGRAPHIC IMAGING BEFORE AND AFTER BALLOON PULMONARY VALVULOPLASTY [J].
FOLLMAN, DF ;
LEVIN, TN ;
LANG, RM ;
FELDMAN, T ;
CARROLL, JD .
AMERICAN HEART JOURNAL, 1993, 125 (01) :259-262
[15]  
GORGE G, 1993, CIRCULATION, V88, P49
[17]   Planimetry of Orifice Area in Aortic Stenosis Using Multiplane Transesophageal Echocardiography [J].
Hoffmann, Rainer ;
Flachskampf, Frank A. ;
Hanrath, Peter .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :529-534
[18]   DETERMINATION OF AORTIC-VALVE ORIFICE AREA IN AORTIC-VALVE STENOSIS BY TWO-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
HOFMANN, T ;
KASPER, W ;
MEINERTZ, T ;
SPILLNER, G ;
SCHLOSSER, V ;
JUST, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (04) :330-335
[19]   CATHETER-BASED INTRAVASCULAR ULTRASOUND DISCRIMINATES BICUSPID FROM TRICUSPID VALVES IN ADULTS WITH CALCIFIC AORTIC-STENOSIS [J].
ISNER, JM ;
LOSORDO, DW ;
ROSENFIELD, K ;
RAMASWAMY, K ;
KELLY, S ;
PASTORE, JO ;
KOSOWSKY, BD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (06) :1310-1317
[20]   COMBINATION BALLOON-ULTRASOUND IMAGING CATHETER FOR PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY - VALIDATION OF IMAGING, ANALYSIS OF RECOIL, AND IDENTIFICATION OF PLAQUE FRACTURE [J].
ISNER, JM ;
ROSENFIELD, K ;
LOSORDO, DW ;
ROSE, L ;
LANGEVIN, RE ;
RAZVI, S ;
KOSOWSKY, BD .
CIRCULATION, 1991, 84 (02) :739-754