Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT

被引:131
作者
Ananthakrishnan, Lakshmi [1 ,2 ]
Rajiah, Prabhakar [2 ]
Ahn, Richard [2 ]
Rassouli, Negin [3 ]
Xi, Yin [2 ]
Soesbe, Todd C. [2 ]
Lewis, Matthew A. [2 ]
Lenkinski, Robert E. [2 ]
Leyendecker, John R. [2 ]
Abbara, Suhny [2 ]
机构
[1] UT Southwestern Med Ctr, Dept Radiol, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
[2] UT Southwestern Med Ctr, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
[3] Univ Hosp Cleveland Med Ctr, 11100 Euclid Ave, Cleveland, OH 44106 USA
关键词
Spectral detector CT; Dual layer detector; Dual energy; VNC; SDCT; Virtual non-contrast; VNC attenuation; Unenhanced versus VNC; DUAL-ENERGY-CT; COMPUTED-TOMOGRAPHY; SYSTEM; UROGRAPHY; ACCURACY;
D O I
10.1007/s00261-016-1036-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To assess virtual non-contrast (VNC) images obtained on a detection-based spectral detector CT scanner and determine how attenuation on VNC images derived from various phases of enhanced CT compare to those obtained from true unenhanced images. Methods: In this HIPAA compliant, IRB approved prospective multi-institutional study, 46 patients underwent pre- and post-contrast imaging on a prototype dual-layer spectral detector CT between October 2013 and November 2015, yielding 84 unenhanced and VNC pairs (25 arterial, 39 portal venous/nephrographic, 20 urographic). Mean attenuation was measured by one of three readers in the liver, spleen, kidneys, psoas muscle, abdominal aorta, and subcutaneous fat. Equivalence testing was used to determine if the mean difference between unenhanced and VNC attenuation was less than 5, 10, or 15 HU. VNC image quality was assessed on a 5 point scale. Results: Mean difference between unenhanced and VNC attenuation was < 15 HU in 92.6%, < 10 HU in 75.2%, and < 5 HU in 44.4% of all measurements. Unenhanced and VNC attenuation were equivalent in all tissues except fat using a threshold of < 10 HU difference (p < 0.05). No significant variation was seen between phases. In fat, VNC overestimated the HU relative to unenhanced images. VNC image quality was rated as excellent or good in 84% of arterial phase and 85% of nephrographic phase cases, but only 40% of urographic phase. Conclusion: VNC images derived from novel dual layer spectral detector CT demonstrate attenuation values similar to unenhanced images in all tissues evaluated except for subcutaneous fat. Further study is needed to determine if attenuation thresholds currently used clinically for common pathology should be adjusted, particularly for lesions containing fat.
引用
收藏
页码:702 / 709
页数:8
相关论文
共 16 条
[1]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]
Managing Incidental Findings on Abdominal CT: White Paper of the ACR Incidental Findings Committee [J].
Berland, Lincoln L. ;
Silverman, Stuart G. ;
Gore, Richard M. ;
Mayo-Smith, William W. ;
Megibow, Alec J. ;
Yee, Judy ;
Brink, James A. ;
Baker, Mark E. ;
Federle, Michael P. ;
Foley, W. Dennis ;
Francis, Isaac R. ;
Herts, Brian R. ;
Israel, Gary M. ;
Krinsky, Glenn ;
Platt, Joel F. ;
Shuman, William P. ;
Taylor, Andrew J. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2010, 7 (10) :754-773
[3]
Incidental adrenal lesions detected on enhanced abdominal dual-energy CT: Can the diagnostic workup be shortened by the implementation of virtual unenhanced images? [J].
Botsikas, Diomidis ;
Triponez, Frederic ;
Boudabbous, Sana ;
Hansen, Catrina ;
Becker, Christoph D. ;
Montet, Xavier .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) :1746-1751
[4]
BROOKS RA, 1978, RADIOLOGY, V126, P255
[5]
Choyke Peter L, 2006, J Am Coll Radiol, V3, P498
[6]
Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images [J].
De Cecco, Carlo Nicola ;
Buffa, Vitaliano ;
Fedeli, Stefano ;
Luzietti, Monica ;
Vallone, Andrea ;
Ruopoli, Roberto ;
Miele, Vittorio ;
Rengo, Marco ;
Paolantonio, Pasquale ;
Enrici, Michelangelo Maurizi ;
Laghi, Andrea ;
David, Vincenzo .
EUROPEAN RADIOLOGY, 2010, 20 (12) :2870-2875
[7]
First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[8]
Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440
[9]
COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[10]
Tin-filter Enhanced Dual-Energy-CT: Image Quality and Accuracy of CT Numbers in Virtual Noncontrast Imaging [J].
Kaufmann, Sascha ;
Sauter, Alexander ;
Spira, Daniel ;
Gatidis, Sergios ;
Ketelsen, Dominik ;
Heuschmid, Martin ;
Claussen, Claus D. ;
Thomas, Christoph .
ACADEMIC RADIOLOGY, 2013, 20 (05) :596-603