Blood flow distributions by microsphere deposition methods

被引:136
作者
Prinzen, FW
Bassingthwaighte, JB
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht, Dept Physiol, NL-6200 MD Maastricht, Netherlands
[2] Univ Washington, Dept Biomed Engn, Seattle, WA 98195 USA
关键词
blood flow; flow heterogeneity; cardiac output; deposition markers; rats; mice; dogs;
D O I
10.1016/S0008-6363(99)00252-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The art and science of the use of deposition markers for the estimation of blood flow distributions throughout the body and within organs is reviewed. Development of diffusible tracer techniques started 50 years ago. Twenty years later, radioactive 15 micron microspheres became the standard marker. Early studies on small animals, fetal sheep in 1967 and rats in 1976, provoked much of the technical development. Needs for avoiding the use of radioactivity, for having long lasting labels, and for providing higher spatial resolution, are driving the continuing exploration of newer techniques using colored and fluorescent microspheres and molecular deposition markers. Strengths and weaknesses of the various methods are compared. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 67 条
  • [1] ABEL FL, 1993, CIRC SHOCK, V41, P156
  • [2] Austin G E, 1993, Am J Cardiovasc Pathol, V4, P352
  • [3] QUANTITATING ERROR IN BLOOD-FLOW MEASUREMENTS WITH RADIOACTIVE MICROSPHERES
    AUSTIN, RE
    HAUCK, WW
    ALDEA, GS
    FLYNN, AE
    COGGINS, DL
    HOFFMAN, JIE
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (01): : H280 - H288
  • [4] Barlow C, 1996, FASEB J, V10, P1871
  • [5] BASSINGTHWAIGHT.JB, 1972, HETEROGENEITY MYOCAR, P197
  • [6] VALIDITY OF MICROSPHERE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS
    BASSINGTHWAIGHTE, JB
    MALONE, MA
    MOFFETT, TC
    KING, RB
    LITTLE, SE
    LINK, JM
    KROHN, KA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (01): : H184 - H193
  • [7] FRACTAL NATURE OF REGIONAL MYOCARDIAL BLOOD-FLOW HETEROGENEITY
    BASSINGTHWAIGHTE, JB
    KING, RB
    ROGER, SA
    [J]. CIRCULATION RESEARCH, 1989, 65 (03) : 578 - 590
  • [8] MOLECULAR AND PARTICULATE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS IN SHEEP
    BASSINGTHWAIGHTE, JB
    MALONE, MA
    MOFFETT, TC
    KING, RB
    CHAN, IS
    LINK, JM
    KROHN, KA
    [J]. CIRCULATION RESEARCH, 1990, 66 (05) : 1328 - 1344
  • [9] Distribution of pulmonary and bronchial blood supply to airways measured by fluorescent microspheres
    Bernard, SL
    Glenny, RW
    Polissar, NL
    Luchtel, DL
    Lakshminarayan, S
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (02) : 430 - 436
  • [10] SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES
    BUCKBERG, GD
    LUCK, JC
    PAYNE, DB
    HOFFMAN, JIE
    ARCHIE, JP
    FIXLER, DE
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) : 598 - &