Design and evaluation of a slot-scanning Full-Field Digital Mammography system

被引:23
作者
Besson, GM [1 ]
Koch, A [1 ]
Tesic, M [1 ]
Sottoriva, R [1 ]
Prieur-Drevron, P [1 ]
Munier, B [1 ]
Calais, E [1 ]
DeGroot, P [1 ]
机构
[1] Fischer Imaging Corp, Denver, CO 80241 USA
来源
MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING | 2002年 / 4682卷
关键词
digital x-ray systems; low dose imaging; high resolution; DQE; MTF; FFDM; slot-scanning;
D O I
10.1117/12.465589
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The FDA has approved the SenoScan slot-scanning Full-Field Digital Mammography (FFDM) system. A high power Tungsten-target x-ray tube enables breast imaging with 0.22 s effective exposure time. A 21-cm x 29-cm area is scanned in less than 6 seconds, at a typical clinical technique of 30 kVp, 170 mA. The detector comprises a Thalium-doped Cesium Iodide scintillator coupled to a combination of four CCDs abutted along their narrow dimension to form a 10-mm by 210-mm slot. With the CCDs operated in time-delay-and-integration mode along the narrow dimension, the system functions in a continuous scanning (and x-ray illumination) mode. The MTF in the standard and high-resolution modes extend to 10-cycles/mm and beyond 14 cycles/mm respectively. The Detective Quantum Efficiency (DQE) curve starts at 50% at DC and extends to 10 cycles/mm in Standard mode. Accordingly the SenoScan system enables screening and diagnostic breast imaging with a limiting resolution approaching that of film-based systems. The overall system design and intrinsic scatter rejection efficiency directly translate in high DQE characteristics that enable screening at a significantly reduced (more than 60% reduction) patient dose.
引用
收藏
页码:457 / 468
页数:4
相关论文
共 10 条
[1]  
Barrett HH., 1981, RADIOLOGICAL IMAGING
[2]  
Boone J., 2000, HDB MED IMAGING, V1
[3]  
Dainty JC., 1974, IMAGE SCI
[4]   MONTE-CARLO CALCULATION OF CONVERSION FACTORS FOR THE ESTIMATION OF MEAN GLANDULAR BREAST DOSE [J].
DANCE, DR .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) :1211-1219
[5]  
JOHNS HE, 1983, PHYSICS RADIOLOGY
[6]   Signal-to-noise ratio and spatial resolution in x-ray electronic imagers: Is the MTF a relevant parameter? [J].
Moy, JP .
MEDICAL PHYSICS, 2000, 27 (01) :86-93
[7]  
ROTHENBERG LN, 1999, CATEGORICAL COURSE D, P91
[8]   Mammography in the 1990s: The United States and Canada [J].
Suleiman, OH ;
Spelic, DC ;
McCrohan, JL ;
Symonds, GR ;
Houn, F .
RADIOLOGY, 1999, 210 (02) :345-351
[9]   Full field digital mammography scanner [J].
Tesic, MM ;
Piccaro, MF ;
Munier, B .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (01) :2-17
[10]  
YAFFE MJ, COMMUNICATION