Optimized flow cytometric assay for the measurement of platelet microparticles in plasma: pre-analytic and analytic considerations

被引:50
作者
Kim, HK
Song, KS
Lee, ES
Lee, YJ
Park, YS
Lee, KR
Lee, SN
机构
[1] Natl Canc Ctr, Res Inst, Hematol Malignancies Branch, Div Special Canc,Ilsan Gu, Gyeonggi Do 411764, South Korea
[2] Yonsei Univ, Coll Med, Dept Clin Pathol, Seoul, South Korea
[3] Natl Canc Ctr, Goyang, Gyeonggi, South Korea
关键词
platelet microparticles; platelet activation; pre-analytical variation; analytical variation; citrate-theophylline-adenosine-dipyridamole; tubes; beta-thromboglobulin;
D O I
10.1097/00001721-200207000-00003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
dPlatelet microparticles (PMP) are submicroscopic membrane vesicles released by platelets during activation. Flow cytometry is the most widely used method for quantifying PMP, but the optimization of the technical method has not yet been fully evaluated. This study was designed to assess the pre-analytical variables including blood sampling conditions, and to evaluate the analytical variations including effect of the platelet-specific antibodies and quantitative beads, precision, linearity and accuracy in comparison with beta-thromboglobulin, which is one of the platelet activation markers. Numbers of PMP collected into citrate-theophylline-adenosine-dipyridamole (CTAD) tubes were increased with time, but to a lesser extent than when collected into sodium citrate tubes. The precision of the PMP assay was relatively high. Excellent linear correlation was observed for dilution linearity. Regarding the platelet-specific antibodies used, anti-CD41a-labeled samples resulted in higher PMP levels than those labeled with anti-CD61 and anti-CD42a. There was no significant difference of PMP counts according to the quantitative beads. The PMP assay is well correlated with beta-thromboglobulin levels. Our findings suggest that blood samples for the PMP assay should be collected in a CTAD tube and delayed measurement is not allowed to avoid artefactual platelet activation. The PMP assay can be used successfully as a useful marker of the detection of in vivo platelet activation, provided that pre-analytical and technical points are optimally taken into consideration. (C) 2002 Lippincott Williams Wilkins.
引用
收藏
页码:393 / 397
页数:5
相关论文
共 15 条
[1]   A novel enzyme immunoassay for plasma thrombospondin:: Comparison with beta-thromboglobulin as platelet activation marker in vitro and in vivo [J].
Bergseth, G ;
Lappegård, KT ;
Videm, V ;
Mollnes, TE .
THROMBOSIS RESEARCH, 2000, 99 (01) :41-50
[2]   Enumeration of CD34+ cells in cord blood: A variation on a single-platform flow cytometric method based on the ISHAGE gating strategy [J].
Brocklebank, AM ;
Sparrow, RL .
CYTOMETRY, 2001, 46 (04) :254-261
[3]  
Combes V, 1997, THROMB HAEMOSTASIS, V77, P220
[4]   HEPARIN INACTIVATION DURING BLOOD-STORAGE - ITS PREVENTION BY BLOOD COLLECTION IN CITRIC-ACID, THEOPHYLLINE, ADENOSINE, DIPYRIDAMOLE - CTAD MIXTURE [J].
CONTANT, G ;
GOUAULTHEILMANN, M ;
MARTINOLI, JL .
THROMBOSIS RESEARCH, 1983, 31 (02) :365-374
[5]   A RADIOIMMUNOASSAY FOR THROMBOSPONDIN, USED IN A COMPARATIVE-STUDY OF THROMBOSPONDIN, BETA-THROMBOGLOBULIN AND PLATELET FACTOR-4 IN HEALTHY-VOLUNTEERS [J].
DAWES, J ;
CLEMETSON, KJ ;
GOGSTAD, GO ;
MCGREGOR, J ;
CLEZARDIN, P ;
PROWSE, CV ;
PEPPER, DS .
THROMBOSIS RESEARCH, 1983, 29 (06) :569-581
[6]  
Escolar G, 2000, THROMB HAEMOSTASIS, V83, P371
[7]  
HAWIGER J, 1989, METHOD ENZYMOL, V169, P191
[8]   Cancer and thrombosis revisited [J].
Hoffman, R ;
Haim, N ;
Brenner, B .
BLOOD REVIEWS, 2001, 15 (02) :61-67
[9]   Platelet microparticles: a wide-angle perspective [J].
Horstman, LL ;
Ahn, YS .
CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 1999, 30 (02) :111-142
[10]  
Joop K, 2001, THROMB HAEMOSTASIS, V85, P810