An evaluation of a 10-gauge vacuum-assisted system for ultrasound-guided excision of clinically benign breast lesions

被引:29
作者
Wang, Zhi Li [1 ]
Li, Jun Lai [1 ]
Su, Li [1 ]
Zhang, Yong Feng [1 ]
Tang, Jie [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Ultrasound, Clin Div Iatrotech, Beijing 100853, Peoples R China
关键词
Ultrasound-guided vacuum-assisted excision; Benign breast disease; PERCUTANEOUS EXCISION; BIOPSY SYSTEM; REMOVAL; MASSES; FIBROADENOMAS; VISUALIZATION; DIAGNOSIS; DEVICE;
D O I
10.1016/j.breast.2009.04.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study was to evaluate a 10-gauge vacuum-assisted system for the excision of clinically benign breast lesions. The minimal excision of 245 lesions in 162 patients was performed with VACORA vacuum-assisted system under the guidance of ultrasound between July 2007 and April 2008. The lesions were category 3 lesions as determined by ultrasound imaging according to Breast Imaging Reporting and Data System (BI-RADS) (n = 208) or had been confirmed as benign by a previous core-needle biopsy (n = 37). As many as 244 lesions were demonstrated to be benign and one case was demonstrated to be malignant by pathology after resection. In the 244 benign lesions, 220 lesions were excised completely as demonstrated by the follow-up ultrasound examination. The malignant lesion was managed with surgical excision. The 10-gauge vacuum-assisted system is highly successful for the excision of benign breast lesions; it is an alternative tool for minimal treatment of benign breast lesions. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:192 / 196
页数:5
相关论文
共 22 条
[1]   Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision:: Utility and cost study in probably benign lesions [J].
Alonso-Bartolomé, P ;
Vega-Bolívar, A ;
Torres-Tabanera, M ;
Ortega, E ;
Acebal-Blanco, M ;
Garijo-Ayensa, F ;
Rodrigo, I ;
Muñoz-Cacho, P .
ACTA RADIOLOGICA, 2004, 45 (04) :390-396
[2]  
[Anonymous], 2013, ATLAS BREAST IMAGING
[3]   Intraoperative ultrasonographically guided excisional biopsy or vacuum-assisted core needle biopsy for nonpalpable breast lesions [J].
Chen, SC ;
Yang, HR ;
Hwang, TL ;
Chen, MF ;
Cheung, YC ;
Hsueh, S .
ANNALS OF SURGERY, 2003, 238 (05) :738-742
[4]   Percutaneous removal of benign breast masses using a vacuum-assisted hand-held device with ultrasound guidance [J].
Fine, RE ;
Boyd, BA ;
Whitworth, PW ;
Kim, JA ;
Harness, JK ;
Burak, WE .
AMERICAN JOURNAL OF SURGERY, 2002, 184 (04) :332-336
[5]   A prospective study of the removal rate of imaged breast lesions by an 11-gauge vacuum-assisted biopsy probe system [J].
Fine, RE ;
Israel, PZ ;
Walker, LC ;
Corgan, KR ;
Greenwald, LV ;
Berenson, JE ;
Boyd, BA ;
Oliver, MK ;
McClure, T ;
Elberfeld, J .
AMERICAN JOURNAL OF SURGERY, 2001, 182 (04) :335-340
[6]   MRI-guided vacuum-assisted breast biopsy with a handheld portable biopsy system [J].
Ghate, SV ;
Rosen, EL ;
Soo, MSC ;
Baker, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :1733-1736
[7]   Long-term outcome of benign fibroadenomas treated by ultrasound-guided percutaneous excision [J].
Grady, Ian ;
Gorsuch, Heidi ;
Wilburn-Bailey, Shelly .
BREAST JOURNAL, 2008, 14 (03) :275-278
[8]  
Hauth E A, 2005, Zentralbl Gynakol, V127, P400, DOI 10.1055/s-2005-836907
[9]   Percutaneous excisional biopsy of impalpable breast lesions under ultrasound visualization [J].
He, Qingqing ;
Fan, Xihong ;
Guan, Yifan ;
Tian, Jun ;
Fan, Ziyi ;
Zheng, Luming .
BREAST, 2008, 17 (06) :666-670
[10]   Percutaneous excisional breast biopsy [J].
Johnson, AT ;
Henry-Tillman, RS ;
Smith, LF ;
Harshfield, D ;
Korourian, S ;
Brown, H ;
Lane, S ;
Colvert, M ;
Klimberg, VS .
AMERICAN JOURNAL OF SURGERY, 2002, 184 (06) :550-554