Phase imaging on a .2-T MR scanner: Application to temperature monitoring during ablation procedures

被引:29
作者
Sinha, S
Oshiro, T
Sinha, U
Lufkin, R
机构
[1] Department of Radiological Sciences, UCLA School of Medicine, Box 951721, Los Angeles, CA 90024
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 05期
关键词
temperature mapping; radiofrequency ablation; phase imaging; keyholing; interventional MRI;
D O I
10.1002/jmri.1880070522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Proton phase shift imaging methods with keyholing were developed to rapidly monitor temperature during MR-guided radiofrequency (RF) interventional procedures on a .2-T open configuration scanner. Temperature calibration was performed on thermally controlled gel phantom and ex vivo bovine liver samples. Keyholing methods were implemented for rapid imaging and tested both in simulation experiments and in the gel phantom. Phase drifts from extraneous sources were monitored and compensated for using reference phantoms. Sequence parameters TE, TR, and flip angle (FA) were optimized for maximum temperature sensitivity and minimum noise., Reduction of phase noise from coupling of the magnetic field to external perturbations using navigator-echo-based correction schemes were also investigated. The extraneous phase drifts from the magnet could be minimized by keeping the electromagnet on continuously. Navigator echo corrected keyholed FLASH sequences (TE = 30 msec, TR = 60 msec, FA = 40 degrees, 64 x 128 matrix) were used to monitor the RF lesioning process in gel phantoms yielding images every 4 seconds with a temperature sensitivity of .015 ppm/degrees C. RF ablation in the bovine tissue was monitored using navigator-echo-corrected keyholed fast low angle shot (FLASH) sequences (TE = 30 msec, TR = 100 msec, FA = 40 degrees, 128 x 256 matrix) with a temporal resolution of 13 seconds and a temperature sensitivity of .007 ppm/degrees C. The results indicate that monitoring of an RF ablation procedure by mapping temperature with sufficient temporal resolution is possible using phase images of FLASH sequences on a .2-T open scanner.
引用
收藏
页码:918 / 928
页数:11
相关论文
共 24 条
[1]   Optimization of spoiled gradient-echo phase imaging for in vivo localization of a focused ultrasound beam [J].
Chung, AH ;
Hynynen, K ;
Colucci, V ;
Oshio, K ;
Cline, HE ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :745-752
[2]  
CHUNG YC, 1996, INT SOC MAGN RES MED, P1743
[3]   MR-GUIDED FOCUSED ULTRASOUND SURGERY [J].
CLINE, HE ;
SCHENCK, JF ;
HYNYNEN, K ;
WATKINS, RD ;
SOUZA, SP ;
JOLESZ, FA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) :956-965
[4]   MR TEMPERATURE MAPPING OF FOCUSED ULTRASOUND SURGERY [J].
CLINE, HE ;
HYNYNEN, K ;
HARDY, CJ ;
WATKINS, RD ;
SCHENCK, JF ;
JOLESZ, FA .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :628-636
[5]   Simultaneous magnetic resonance phase and magnitude temperature maps in muscle [J].
Cline, HE ;
Hynynen, K ;
Schneider, E ;
Hardy, CJ ;
Maier, SE ;
Watkins, RD ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :309-315
[6]  
COMTE P, 1987, PRESURGICAL EVALUATI, P109
[7]  
COSMAN ER, 1994, RADIOFREQUENCY CATHE, P13
[8]   NAVIGATED DIFFUSION IMAGING OF NORMAL AND ISCHEMIC HUMAN BRAIN [J].
DECRESPIGNY, AJ ;
MARKS, MP ;
ENZMANN, DR ;
MOSELEY, ME .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :720-728
[9]   THE PROTON-RESONANCE-FREQUENCY-SHIFT METHOD COMPARED WITH MOLECULAR-DIFFUSION FOR QUANTITATIVE MEASUREMENT OF 2-DIMENSIONAL TIME-DEPENDENT TEMPERATURE DISTRIBUTION IN A PHANTOM [J].
DEPOORTER, J ;
DEWAGTER, C ;
DEDEENE, Y ;
THOMSEN, C ;
STAHLBERG, F ;
ACHTEN, E .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :234-241
[10]  
DEPOORTER J, 1995, MAGNET RESON MED, V33, P74, DOI 10.1002/mrm.1910330111