Final clearance criteria after mould remediation

被引:8
作者
Quezada, NV
Lange, JH
机构
[1] Envirosafe Training & Consultants, Pittsburgh, PA 15239 USA
[2] ADS Consulting, Las Vegas, NV USA
关键词
mould final clearance; abatement; remediation; sampling;
D O I
10.1177/1420326X04044208
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Final clearance sampling practices for mould abatement projects have not been evaluated. This paper proposes procedures to remedy this. It is suggested that following remediation and after the visual inspection at least five to seven air samples should be collected. These sampling practices can also be used to screen for mould problems as part of a visual inspection and to assist in recognizing a problem dwelling. It is suggested that screening should involve taking at least four samples. To determine if the air concentration of mould is elevated it is necessary to sample inside and outside the building (abatement area). Since these samples have been shown to be non-normal in distribution, transformation is required or non-parametric statistic testing must be performed to determine whether the airborne mould concentration is elevated inside the area of interest (the building).
引用
收藏
页码:199 / 203
页数:5
相关论文
共 32 条
[1]   Emission and evolution of air-borne microflora in slaughter houses [J].
Adeeb, F ;
Shooter, D .
INDOOR AND BUILT ENVIRONMENT, 2003, 12 (03) :179-184
[2]  
Aizenberg V, 2000, AIHAJ, V61, P855, DOI 10.1080/15298660008984598
[3]   Humid building problems in Mauritius [J].
Bholah, R ;
Subratty, AH .
INDOOR AND BUILT ENVIRONMENT, 2003, 12 (04) :221-225
[4]   Toxic mold: phantom risk vs science [J].
Chapman, JA ;
Terr, AI ;
Jacobs, RL ;
Charlesworth, EN ;
Bardana, EJ .
ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2003, 91 (03) :222-232
[5]  
DEKOSTER JA, 1995, AM IND HYG ASSOC J, V56, P573, DOI 10.1202/0002-8894(1995)056<0573:BCINCA>2.0.CO
[6]  
2
[7]   Environmental control for fungal allergen exposure [J].
Eggleston, PA .
CURRENT ALLERGY AND ASTHMA REPORTS, 2003, 3 (05) :424-429
[8]   Indoor airborne fungal spores, house dampness and associations with environmental factors and respiratory health in children [J].
Garrett, MH ;
Rayment, PR ;
Hooper, MA ;
Abramson, MJ ;
Hooper, BM .
CLINICAL AND EXPERIMENTAL ALLERGY, 1998, 28 (04) :459-467
[9]  
Gots RE, 2003, AIHA J-J SCI OCCUP E, V64, P427, DOI 10.1080/15428110308984836
[10]   Risks caused by airborne microbes in hospitals - Source control is important [J].
Kalliokoski, P .
INDOOR AND BUILT ENVIRONMENT, 2003, 12 (1-2) :41-46