Emission and evolution of air-borne microflora in slaughter houses

被引:4
作者
Adeeb, F
Shooter, D
机构
[1] Environm Protect Author, Adelaide, SA, Australia
[2] Univ Auckland, Sch Geog & Environm Sci, Auckland 1, New Zealand
关键词
indoor bacteria; indoor fungi; animal houses; ventilation;
D O I
10.1177/1420326X03012003005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The indoor environment can potentially place human occupants at greater risk than the outside environment, because enclosed spaces help to confine aerosols and allow them to build up to potentially infectious levels. The concentration of air-borne microflora (bacteria and fungi) was determined over a 12-month period in four slaughter houses in the city of Lahore, Pakistan. The overall level of airborne microflora (i.e. 3.9-8.5 log CFU m(-3)) obtained in Lahore was higher compared to the level of indoor microflora (i.e. 3.7-6.43 log CFU m(-3)) reported for other livestock buildings surveyed in 4 European countries (England, Germany, Denmark and The Netherlands). Differences in concentration may be due to the generation rate of air-borne microflora, accumulation potential and clearance by various routes, mainly ventilation and mechanical coagulation (i.e. settlement).
引用
收藏
页码:179 / 184
页数:6
相关论文
共 27 条
[1]   Development and evaluation of a new personal sampler for culturable airborne microorganisms [J].
Agranovski, IE ;
Agranovski, V ;
Reponen, T ;
Willeke, K ;
Grinshpun, SA .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (05) :889-898
[2]  
Alexopoulos CJ., 1995, INTRO MYCOLOGY, V4
[3]   NEW SAMPLER FOR THE COLLECTION, SIZING, AND ENUMERATION OF VIABLE AIRBORNE PARTICLES [J].
ANDERSEN, AA .
JOURNAL OF BACTERIOLOGY, 1958, 76 (05) :471-484
[4]  
[Anonymous], 1991, INDOOR AIR POLLUTION
[5]   Microbial air pollution caused by intensive broiler chicken breeding [J].
Baykov, B ;
Stoyanov, M .
FEMS MICROBIOLOGY ECOLOGY, 1999, 29 (04) :389-392
[6]   The indoor environment of a modern museum building, the Sainsbury Centre for Visual Arts, Norwich, UK [J].
Brimblecombe, P ;
Blades, N ;
Camuffo, D ;
Sturaro, G ;
Valentino, A ;
Gysels, K ;
Van Grieken, R ;
Busse, HJ ;
Kim, O ;
Ulrych, U ;
Wieser, M .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (03) :146-164
[8]   Comparison of indoor and outdoor concentrations of CO at a public school. Evaluation of an indoor air quality model [J].
Chaloulakou, A ;
Mavroidis, I .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (11) :1769-1781
[9]  
DAMATO G, 1984, ANN ALLERGY, V52, P363
[10]  
DONHAM KJ, 1989, AGRI-PRACTICE, V10, P15