Fused-core, sub-2 μm packings, and monolithic HPLC columns: a comparative evaluation

被引:60
作者
Brice, Richard W. [1 ]
Zhang, Xin [1 ]
Colon, Luis A. [1 ]
机构
[1] SUNY Buffalo, Dept Chem, Buffalo, NY 14260 USA
基金
美国国家科学基金会;
关键词
Fused-core; Monolithic columns; Sub-2 mu m particles; Packed columns; Ultrahigh pressure LC; PERFORMANCE LIQUID-CHROMATOGRAPHY; STATIONARY PHASES; CONTINUOUS BEDS; PARTICLES; MICROPARTICULATE; EFFICIENCY; PEPTIDES; BEHAVIOR;
D O I
10.1002/jssc.200900091
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three different HPLC column technologies (i.e., monolith, fused-core particles, and sub-2 mu m particles) were evaluated, comparing van Deemter plots, speed of analysis, back pressure, and mobile phase consumption. Very high linear velocities (similar to 12 mm/s) were achieved with the monolithic column using modest pressure (110 bar) at the expense of high mobile phase consumption. The minimum plate height of the monolith was similar to that of a 3 mu m-particle packed column (i.e., h = 8 mu m), operated at optimal linear velocities; the monolithic column showed substantially lower mass transfer dependence, however. The 2.7 mu m fused-core packing material yielded efficiencies closer to the sub-2 mu m material than to the 3 mu m-particle packed column and could be operated at high flow rates. The fused-core column was able to achieve linear velocities similar to those attained on the sub-2 mu m column, staying below 620 bar instead of almost near 1030 bar required by the sub-2 mu m material. The lack of pH stability of the monolithic column prevented its use to separate basic compounds (i.e., tricyclic antidepressants) at high pH. Best separation of these components at high pH was achieved using the column packed with 1.7 mu m hybrid material.
引用
收藏
页码:2723 / 2731
页数:9
相关论文
共 33 条
[1]   Ultrahigh-pressure liquid chromatography using a 1-mm id column packed with 1.5-μm porous particles [J].
Anspach, Jason A. ;
Maloney, Todd D. ;
Colon, Luis A. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (08) :1207-1213
[2]   Comparative study on the column performance of microparticulate 5-μm C18-bonded and monolithic C18-bonded reversed-phase columns in high-performance liquid chromatography [J].
Bidlingmaier, B ;
Unger, KK ;
von Doehren, N .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :11-16
[3]  
Bokaru M.A., 2002, J CHROMATOGR A, V975, P275
[4]   Detailed characterisation of the flow resistance of commercial sub-2 μm reversed-phase columns [J].
Cabooter, Deirdre ;
Billen, Jeroen ;
Terryn, Herman ;
Lynen, Frederic ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1178 (1-2) :108-117
[5]   HIGH-SPEED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS [J].
CHEN, H ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) :3-20
[6]   FACTORS DETERMINING FLOW-RATE IN CHROMATOGRAPHIC COLUMNS [J].
CRAMERS, CA ;
RIJKS, JA ;
SCHUTJES, CPM .
CHROMATOGRAPHIA, 1981, 14 (07) :439-444
[7]   Fused-core particle technology as an alternative to sub-2-αm particles to achieve high separation efficiency with low backpressure [J].
Cunliffe, Jennifer M. ;
Maloney, Todd D. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (18) :3104-3109
[8]   Selection of comparison criteria and experimental conditions to evaluate the kinetic performance of monolithic and packed-bed columns [J].
Eeltink, Sebastiaan ;
Gzil, Piotr ;
Kok, Wim Th. ;
Schoenmakers, Peter J. ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1130 (01) :108-114
[9]   Improved protein recovery in reversed-phase liquid chromatography by the use of ultrahigh pressures [J].
Eschelbach, JW ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 2006, 78 (05) :1697-1706
[10]   Practical aspects of fast reversed-phase high-performance liquid chromatography using 3 μm particle packed columns and monolithic columns in pharmaceutical development and production working under current good manufacturing practice [J].
Gerber, F ;
Krummen, M ;
Potgeter, H ;
Roth, A ;
Siffrin, C ;
Spoendlin, C .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1036 (02) :127-133