The effect of varying magnitudes of whole-body vibration on several skeletal sites in mice

被引:93
作者
Christiansen, Blaine A.
Silva, Matthew J.
机构
[1] St Louis Univ, Dept Orthopaed Surg, St Louis, MO 63110 USA
[2] St Louis Univ, Dept Biomed Engn, St Louis, MO 63110 USA
关键词
osteoporosis; trabecular bone; mechanical loading; murine; MicroCT; osteoprogenitor cells; bone formation;
D O I
10.1007/s10439-006-9133-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It has been reported that whole-body vibration (WBV) is anabolic to trabecular bone in animal models and humans. It is likely that this anabolic response does not occur uniformly throughout the entire body. Two factors that may affect the observed anabolic response are vibration magnitude and skeletal site of interest. In this study, mice were loaded with WBV of varying magnitudes. After five weeks of loading, bone marrow was flushed from tibias in order to quantify osteoprogenitor cells. Staining with alizarin red (an indicator of mineralization) showed a significant decrease in percent stained area in the 0.3 g loaded group compared to the control group and the 1.0 g group. MicroCT analysis was performed at five skeletal sites: the proximal tibial metaphysis, femoral condyles, distal femoral metaphysis, proximal femur, and L5 vertebral body. Increasing magnitudes of WBV were associated with a non-dose-dependent increase in trabecular bone volume (BV/TV) at the proximal tibial metaphysis, although other sites were unresponsive. There were statistically significant increases in BV/TV in the 0.1 g group (32% increase) and 1.0 g group (43% increase) compared to control (p < 0.05). The 0.1 g and 1.0 g groups also had higher BV/TV than the 0.3 g loaded group. If this non-dose-dependent phenomenon is verified by future studies, it suggests that a range of magnitudes should be examined for each application of WBV.
引用
收藏
页码:1149 / 1156
页数:8
相关论文
共 31 条
[1]   Mechanical stimulation in the form of vibration prevents postmenopausal bone loss in ovariectomized rats [J].
Flieger, J ;
Karachalios, T ;
Khaldi, L ;
Raptou, P ;
Lyritis, G .
CALCIFIED TISSUE INTERNATIONAL, 1998, 63 (06) :510-514
[2]   Whole-body vibration in the skeleton: Development of a resonance-based testing device [J].
Fritton, JC ;
Rubin, CT ;
Qin, YX ;
McLeod, KJ .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (05) :831-839
[3]  
FUNKOSHI M, 2003, J OCCUP HEALTH, V46, P119
[4]   Rat Hindlimb unloading by tail suspension reduces osteoblast differentiation, induces IL-6 secretion, and increases bone resorption in ex vivo cultures [J].
Grano, M ;
Mori, G ;
Minielli, V ;
Barou, O ;
Colucci, S ;
Giannelli, G ;
Alexandre, C ;
Zallone, AZ ;
Vico, L .
CALCIFIED TISSUE INTERNATIONAL, 2002, 70 (03) :176-185
[5]   A new method for the model-independent assessment of thickness in three-dimensional images [J].
Hildebrand, T ;
Ruegsegger, P .
JOURNAL OF MICROSCOPY-OXFORD, 1997, 185 :67-75
[6]   Genetic predisposition to low bone mass is paralleled by an enhanced sensitivity to signals anabolic to the skeleton [J].
Judex, S ;
Donahue, LR ;
Rubin, C .
FASEB JOURNAL, 2002, 16 (08) :1280-+
[7]   Adaptations of trabecular bone to low magnitude vibrations result in more uniform stress and strain under load [J].
Judex, S ;
Boyd, S ;
Qin, YX ;
Turner, S ;
Ye, K ;
Müller, R ;
Rubin, C .
ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (01) :12-20
[8]  
Kostenuik PJ, 1997, AM J PHYSIOL-ENDOC M, V273, pE1133
[9]  
LEI X, 2005, 51 ANN M ORTH RES SO
[10]   Dynamic response of the standing human body exposed to vertical vibration: Influence of posture and vibration magnitude [J].
Matsumoto, Y ;
Griffin, MJ .
JOURNAL OF SOUND AND VIBRATION, 1998, 212 (01) :85-107