Imaging of head and neck tumors -: methods:: CT, spiral-CT, multislice-spiral-CT

被引:41
作者
Baum, U [1 ]
Greess, H [1 ]
Lell, M [1 ]
Nömayr, A [1 ]
Lenz, M [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-91054 Erlangen, Germany
关键词
computed tomography; helical computed tomography; computed tomography technology; thin-section computed tomography; three-dimensional computed tomography; computed tomography tissue characterization; head and neck neoplasms; CT scanner;
D O I
10.1016/S0720-048X(99)00139-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the transverse plane but also in the coronal plane. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 29 条
[1]   COMPUTED-TOMOGRAPHY OF CERVICAL LYMPH-NODE METASTASES IN MALIGNANT-TUMORS OF THE HEAD AND NECK [J].
BAHREN, W ;
HAASE, S ;
LENZ, M ;
RANZINGER, G ;
WIERSCHIN, W .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1983, 139 (03) :281-284
[2]  
Bahren W, 1982, Rofo, V136, P525, DOI 10.1055/s-2008-1056094
[3]  
Beus J, 1995, Aktuelle Radiol, V5, P189
[4]  
Claussen C D, 1982, Rofo, V137, P212, DOI 10.1055/s-2008-1056187
[5]   BOLUS GEOMETRY AND DYNAMICS AFTER INTRAVENOUS CONTRAST-MEDIUM INJECTION [J].
CLAUSSEN, CD ;
BANZER, D ;
PFRETZSCHNER, C ;
KALENDER, WA ;
SCHORNER, W .
RADIOLOGY, 1984, 153 (02) :365-368
[6]  
Cohnen M, 1998, Aktuelle Radiol, V8, P34
[7]   Dosage measurement in spiral CT examinations in the head and neck region [J].
Cohnen, M ;
Cohnen, B ;
Ewen, K ;
Teubert, G ;
Modder, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (05) :474-479
[8]   COMPUTED TOMOGRAPHIC SCANNING IN PATIENTS WITH CARCINOMA OF THE TONGUE [J].
COOKE, J ;
PARSONS, C .
CLINICAL RADIOLOGY, 1989, 40 (03) :254-256
[9]  
Ehritt-Braun C, 1994, Aktuelle Radiol, V4, P222
[10]   COMPUTED-TOMOGRAPHY OF THE NORMAL LARYNX DURING QUIET BREATHING AND PHONATION [J].
GAMSU, G ;
MARK, AS ;
WEBB, WR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (03) :353-360