Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling:: Comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography -: Pilot study

被引:59
作者
Spuentrup, E
Katoh, M
Buecker, A
Manning, WJ
Schaeffter, T
Nguyen, TH
Kühl, HP
Stuber, M
Botnar, RM
Günther, RW
机构
[1] Rhein Westfal TH Aachen, Univ Hosp Aachen, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Rhein Westfal TH Aachen, Univ Hosp Aachen, Med Clin, D-52057 Aachen, Germany
[3] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[4] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[5] Harvard Univ, Sch Med, Boston, MA 02215 USA
[6] Philips Res Labs, Hamburg, Germany
[7] Philips Med Syst, Best, Netherlands
关键词
coronary angiography; comparative studies; coronary vessels; MR; magnetic resonance (MR); k-space magnetic resonance (MR); motion correction; three-dimentional;
D O I
10.1148/radiol.2312030451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space. sampling SSFP coronary MR angiography, and gradient echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and, objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vesses sharpness. ratio and vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P < .05). Contrast-to-noise ratio with radial SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders. (C) RSNA, 2004.
引用
收藏
页码:581 / 586
页数:6
相关论文
共 31 条
  • [1] Barish M A, 1999, Magn Reson Imaging Clin N Am, V7, P289
  • [2] Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography
    Börnert, P
    Stuber, M
    Botnar, RM
    Kissinger, KV
    Koken, P
    Spuentrup, E
    Manning, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 789 - 794
  • [3] Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    Botnar, RM
    Stuber, M
    Danias, PG
    Kissinger, KV
    Manning, WJ
    [J]. CIRCULATION, 1999, 99 (24) : 3139 - 3148
  • [4] CARR J, 2000, P 8 M INT SOC MAGN R, P199
  • [5] DEIMLING M, 2000, P 8 ANN M ISMRM DENV, P1500
  • [6] Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
  • [7] Breath-hold three-dimensional true-FISP imaging of coronary arteries using asymmetric sampling
    Deshpande, VS
    Shea, SM
    Chung, YC
    McCarthy, RM
    Finn, JP
    Li, DB
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 473 - 478
  • [8] 3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries
    Deshpande, VS
    Shea, SM
    Laub, G
    Simonetti, OP
    Finn, JP
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 494 - 502
  • [9] Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T
    Duerk, JL
    Lewin, JS
    Wendt, M
    Petersilge, C
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 203 - 208
  • [10] Improved visualization of coronary arteries using a new three-dimensional submillimeter MR coronary angiography sequence with balanced gradients
    Giorgi, B
    Dymarkowski, S
    Maes, F
    Kouwenhoven, M
    Bogaert, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) : 901 - 910