A synthetic fiber-reinforced stentless heart valve

被引:31
作者
Cacciola, G [1 ]
Peters, GWM [1 ]
Baaijens, FPT [1 ]
机构
[1] Eindhoven Univ Technol, Dept Mech Engn, NL-5600 Eindhoven, Netherlands
关键词
heart valve prosthesis; leaflet fiber-reinforcement; synthetic heart valves; stentless valve;
D O I
10.1016/S0021-9290(00)00003-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
There is strong evidence that Failure of bioprosthetic and synthetic valves occurs as a consequence of high tensile and bending stresses, acting on the leaflets during opening and closing. In stented prostheses, whether synthetic or biological, the absence of contraction of the aortic base causes the leaflets to be subjected to an unphysiological degree of flexure, which is also related to calcification. However, a stentless synthetic valve, which has a flexible aorta base, can be a good alternative for stented synthetic valves. Moreover, fiber-reinforcement is assumed to lead to a decrease of tears and perforation as a result of reduced stresses in the weaker parts of the leaflets in their closed configuration. The manufacturing method for a stentless, fiber-reinforced, synthetic valve is presented. Prototypes are tested in a pulse duplicator system. The: results show that the mean systolic pressure difference is very low, while the high regurgitation (up to 26%) is probably caused by a too small coaptation area of the leaflets. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:653 / 658
页数:6
相关论文
共 14 条
[1]  
Cacciola G., 1996, Biomimetics, V4, P83
[2]   A three-dimensional mechanical analysis of a stentless fibre-reinforced aortic valve prosthesis [J].
Cacciola, G ;
Peters, GWM ;
Schreurs, PJG .
JOURNAL OF BIOMECHANICS, 2000, 33 (05) :521-530
[3]  
CACCIOLA G, 1998, THESIS EINDHOVEN U T
[4]  
De Hart J, 1998, J BIOMECH, V31, P629, DOI 10.1016/S0021-9290(98)00063-3
[5]   Hemodynamic performance of the PRIMA(TM) Edwards stentless aortic xenograft: Early results of a multicenter clinical trial [J].
Dossche, K ;
Vanermen, H ;
Daenen, W ;
Pillai, R ;
Konertz, W .
THORACIC AND CARDIOVASCULAR SURGEON, 1996, 44 (01) :11-14
[6]   AORTIC-VALVE REPLACEMENT - IS THE STENTLESS XENOGRAFT AN ALTERNATIVE TO THE HOMOGRAFT - EARLY RESULTS OF A RANDOMIZED STUDY [J].
GROSS, C ;
HARRINGER, W ;
MAIR, R ;
WIMMERGREINECKER, G ;
KLIMA, U ;
SIHORSCH, K ;
HOFMANN, R ;
BERAN, H ;
BRUCKE, P .
ANNALS OF THORACIC SURGERY, 1995, 60 (02) :S418-S421
[7]  
HILBERT SL, 1987, J THORAC CARDIOV SUR, V94, P419
[8]   NEW J-3 FLEXIBLE-LEAFLET POLYURETHANE HEART-VALVE PROSTHESIS WITH IMPROVED HYDRODYNAMIC PERFORMANCE [J].
JANSEN, J ;
WILLEKE, S ;
REINERS, B ;
HARBOTT, P ;
REUL, H ;
RAU, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (10) :655-660
[9]  
Leat M E, 1995, Proc Inst Mech Eng H, V209, P65, DOI 10.1243/PIME_PROC_1995_209_318_02
[10]   A SYNTHETIC LEAFLET HEART-VALVE WITH IMPROVED OPENING CHARACTERISTICS [J].
LEAT, ME ;
FISHER, J .
MEDICAL ENGINEERING & PHYSICS, 1994, 16 (06) :470-476