Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging

被引:65
作者
Cherry, SR
Shao, YP
Siegel, S
Silverman, RW
Mumcuoglu, E
Meadors, K
Phelps, ME
机构
[1] Crump Institute for Biological Imaging, Department of Molecular and Medical Pharmacology, UCLA School of Medicine, Los Angeles, CA
关键词
D O I
10.1109/23.507249
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report the results from a new high resolution gamma ray imaging detector designed for use in a positron emission tomography (PET) system dedicated to small animal imaging. The detectors consist of an 8 x 8 array of 2 x 2 x 10 mm bismuth germanate (BGO) crystals coupled by 2 mm diameter double clad optical fibers to a 64 pixel multi-channel photomultiplier tube (MC-PMT). A charge division readout board is used to convert the 64 output channels into four position sensitive signals which determine the crystal of interaction. Measurements with a pair of these detectors demonstrate an intrinsic spatial resolution of 1.4 mm, a coincidence timing resolution of 15 ns and an energy resolution ranging between 35 and 60%. Based on these encouraging results, the design for a dedicated animal PET tomograph is proposed and simulations of this system project a reconstructed resolution of less than 2 mm within a 5 cm diameter transaxial field of view.
引用
收藏
页码:1932 / 1937
页数:6
相关论文
共 22 条
[1]   PERFORMANCE OF MULTICLAD SCINTILLATING AND CLEAR WAVE-GUIDE FIBERS READ-OUT WITH VISIBLE-LIGHT PHOTON COUNTERS [J].
BAUMBAUGH, B ;
ERDMAN, J ;
GASKELL, D ;
LU, Q ;
MARCHANT, J ;
RUCHTI, R ;
WAYNE, M ;
COOPER, C ;
HINSON, J ;
KOLTICK, DS ;
SCHMITZ, CJ ;
SHIBATA, EI ;
CHUNG, M ;
MARGULIES, S ;
SOLOMON, J ;
ATAC, M ;
BAUMBAUGH, A ;
BROSS, AD ;
ELIAS, J ;
MISHINA, M ;
CHANEY, R ;
HAMMACK, H ;
ADAMS, D ;
BIRD, F ;
LEWIS, RA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 345 (02) :271-278
[2]   A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY [J].
CASEY, ME ;
NUTT, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :460-463
[3]   A COMPARISON OF PET DETECTOR MODULES EMPLOYING RECTANGULAR AND ROUND PHOTOMULTIPLIER TUBES [J].
CHERRY, SR ;
TORNAI, MP ;
LEVIN, CS ;
SIEGEL, S ;
HOFFMAN, EJ ;
ANDREACO, MS ;
WILLIAMS, CW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1064-1068
[4]   COLLECTION OF SCINTILLATION LIGHT FROM SMALL BGO CRYSTALS [J].
CHERRY, SR ;
SHAO, YP ;
TORNAI, MP ;
SIEGEL, S ;
RICCI, AR ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1058-1063
[5]   TEST OF A NEW 64-CHANNEL PMT FOR IMAGING [J].
COMBY, G ;
MEUNIER, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (01) :246-260
[6]  
CUTLER PD, 1992, J NUCL MED, V33, P595
[7]   AN EVALUATION OF A TWO-DIMENSIONAL ARRAY DETECTOR FOR HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :264-272
[8]   STUDIES OF POSITION-SENSITIVE PHOTOMULTIPLIERS IN READOUT OF SCINTILLATING AND WAVESHIFTING FIBERS [J].
MAJEWSKI, S ;
KROSS, B ;
WOJCIK, R ;
WEISENBERGER, A ;
ZORN, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 323 (1-2) :489-504
[9]  
MARRIOTT CJ, 1994, J NUCL MED, V35, P1390
[10]  
MCDANIEL D, 1992, IEEE NUCL SCI MED IM, P1739