A COMPARISON OF PET DETECTOR MODULES EMPLOYING RECTANGULAR AND ROUND PHOTOMULTIPLIER TUBES

被引:48
作者
CHERRY, SR [1 ]
TORNAI, MP [1 ]
LEVIN, CS [1 ]
SIEGEL, S [1 ]
HOFFMAN, EJ [1 ]
ANDREACO, MS [1 ]
WILLIAMS, CW [1 ]
机构
[1] CTI PET SYST INC,KNOXVILLE,TN
关键词
D O I
10.1109/23.467748
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have compared the high resolution BGO detector blocks from the EXACT HR PET system which use two dual-cathode rectangular photomultiplier (PM) tubes with a new block design, the EXACT HR PLUS, which uses four round PM tubes. Despite the lower coupling area between photocathode and scintillator, the HR PLUS block compares favorably with the HR block. The energy resolution averages 20% for the HR PLUS block and 23% for the HR block, with efficiency variations of 17% in both blocks. Additional measurements were carried out on the HR PLUS block to characterize depth of interaction effects and cross-talk between elements. Coincidence line spread function measurements had a FWHM of 3.0 mm in the axial direction and 2.9 mm in the transaxial direction. In light of these results, limitations of the BGO block design are discussed and some solutions proposed.
引用
收藏
页码:1064 / 1068
页数:5
相关论文
共 12 条
[1]   A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY [J].
CASEY, ME ;
NUTT, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :460-463
[2]   3D PET USING A CONVENTIONAL MULTISLICE TOMOGRAPH WITHOUT SEPTA [J].
CHERRY, SR ;
DAHLBOM, M ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :655-668
[3]   USE OF DIGITAL FRONT-END ELECTRONICS FOR OPTIMIZATION OF A MODULAR PET DETECTOR [J].
CUTLER, PD ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :408-418
[4]   AN EVALUATION OF A TWO-DIMENSIONAL ARRAY DETECTOR FOR HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :264-272
[5]   A STUDY OF DATA LOSS AND MISPOSITIONING DUE TO PILEUP IN 2-D DETECTORS IN PET [J].
GERMANO, G ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :671-675
[6]   FAST, HIGH-DENSITY AVALANCHE PHOTODIODE-ARRAY [J].
GRAMSCH, E ;
SZAWLOWSKI, M ;
ZHANG, S ;
MADDEN, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :762-766
[7]   PERFORMANCE OF A PET DETECTOR MODULE UTILIZING AN ARRAY OF SILICON PHOTODIODES TO IDENTIFY THE CRYSTAL OF INTERACTION [J].
MOSES, WW ;
DERENZO, SE ;
NUTT, R ;
DIGBY, WM ;
WILLIAMS, CW ;
ANDREACO, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1036-1040
[8]  
MOSES WW, 1993, J NUCL MED, V34, pP101
[9]   TESTING 144-CRYSTAL AND 256-CRYSTAL BGO BLOCK DETECTORS [J].
ROGERS, JG ;
NUTT, R ;
ANDREACO, M ;
WILLIAMS, CW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1423-1429
[10]   EFFECT OF REFRACTION INDEX AND LIGHT SHARING ON DETECTOR ELEMENT IDENTIFICATION FOR 2D DETECTOR MODULES IN POSITRON EMISSION TOMOGRAPHY [J].
TORNAI, MP ;
HOFFMAN, EJ ;
CHERRY, SR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3) :618-622