PERFORMANCE OF A PET DETECTOR MODULE UTILIZING AN ARRAY OF SILICON PHOTODIODES TO IDENTIFY THE CRYSTAL OF INTERACTION

被引:34
作者
MOSES, WW [1 ]
DERENZO, SE [1 ]
NUTT, R [1 ]
DIGBY, WM [1 ]
WILLIAMS, CW [1 ]
ANDREACO, M [1 ]
机构
[1] CTI INC,KNOXVILLE,TN 37933
关键词
D O I
10.1109/23.256708
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present initial performance results for a new multi-layer PET detector module consisting of an array of 3 mm square by 30 mm deep BGO crystals coupled on one end to a single photomultiplier, tube and on the opposite end to an array of 3 mm square silicon photodiodes. The photomultiplier tube provides an accurate timing pulse and energy discrimination for the all the crystals in the module, while the silicon photodiodes identify the crystal of interaction. When a. single BGO crystal at +25-degrees-C is excited with 511 keV photons, we measure a photodiode signal centered at 700 electrons (e-) with noise of 375 e- fwhm. When a four-crystal/photodiode module is excited with a collimated line source of 511 keV photons, the crystal of interaction is correctly identified 82% of the time. The misidentification rate can be greatly reduced and an 8 x 8 crystal/photodiode module constructed by using thicker depletion layer photodiodes or cooling to 0-degrees-C.
引用
收藏
页码:1036 / 1040
页数:5
相关论文
共 10 条
[1]   A HIGH-RESOLUTION DETECTION SYSTEM FOR POSITRON TOMOGRAPHY [J].
BARTON, JB ;
HOFFMAN, EJ ;
IWANCZYK, JS ;
DABROWSKI, AJ ;
KUSMISS, JH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (01) :671-675
[2]   HYBRID MERCURIC IODIDE (HGI2) - GADOLINIUM ORTHOSILICATE (GSO) DETECTOR FOR PET [J].
DAHLBOM, M ;
MANDELKERN, MA ;
HOFFMAN, EJ ;
RICCI, AR ;
BARTON, JB ;
IWANCZYK, JS ;
DABROWSKI, AJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) :533-537
[3]   HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY USING SMALL BISMUTH-GERMANATE CRYSTALS AND INDIVIDUAL PHOTOSENSORS [J].
DERENZO, SE ;
BUDINGER, TF ;
VULETICH, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (01) :665-670
[4]   INITIAL CHARACTERIZATION OF A BGO-PHOTODIODE DETECTOR FOR HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY [J].
DERENZO, SE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :620-626
[5]   GAMMA-RAY SPECTROSCOPY USING SMALL, COOLED BISMUTH-GERMANATE SCINTILLATORS AND SILICON PHOTODIODES [J].
DERENZO, SE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 219 (01) :117-122
[7]   HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY WITH A PROTOTYPE CAMERA BASED ON SOLID-STATE SCINTILLATION DETECTORS [J].
LECOMTE, R ;
CADORETTE, J ;
JOUAN, A ;
HEON, M ;
ROULEAU, D ;
GAUTHIER, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :805-811
[8]  
MELCHER CL, 1985, IEEE T NUCL SCI, V32, P529, DOI 10.1109/TNS.1985.4336887
[9]  
RAJESWARAN S, 1993, UNPUB IEEE T NUCL SC, V40
[10]   AN IMPROVED MULTICRYSTAL 2-D BGO DETECTOR FOR PET [J].
ROGERS, JG ;
TAYLOR, AJ ;
RAHIMI, MF ;
NUTT, R ;
ANDREACO, M ;
WILLIAMS, CW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1063-1068